“Monte Carlo simulation for X-ray fluorescence spectroscopy”. Vincze L, Janssens K, Vekemans B, Adams F page 435 (2004).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Non-destructive micoranalysis of cultural heritage materials”. Janssens K, Van Grieken R page 800 p. (2004).
Keywords: ME3 Book as editor; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Oxidation states of uranium in depleted uranium particles from Kuwait”. Salbu B, Janssens K, Lind OC, Proost K, Gijsels L, Danesi PR, Journal of environmental radioactivity 78, 125 (2004). http://doi.org/10.1016/J.JENVAD.2004.04.001
Abstract: The oxidation states of uranium in depleted uranium (DU) particles were determined by synchrotron radiation based mu-XANES, applied to individual particles isolated from selected samples collected at different sites in Kuwait. Based on scanning electron microscopy with X-ray microanalysis prior to mu-XANES, DU particles ranging from sub-microns to several hundred micrometers were observed. The.median particle size depended on sources and sampling sites; small-sized particles (median 13 mum) were identified in swipes taken from the inside of DU penetrators holes in tanks and in sandy soil collected below DU penetrators, while larger particles (median 44 mum) were associated with fire in a DU ammunition storage facility. Furthermore, the U-236/U-235 ratios obtained from accelerator mass spectrometry demonstrated that uranium in the DU particles originated from reprocessed fuel (about 10(-2) in DU from the ammunition facility, about 10(-3) for DU in swipes). Compared to well-defined standards, all investigated DU particles were oxidized. Uranium particles collected from swipes were characterized as UO2, U3O8 or a mixture of these oxidized forms, similar to that observed in DU affected areas in Kosovo. Uranium particles formed during fire in the DU ammunition facility were, however, present as oxidation state +5 and +6, with XANES spectra similar to solid uranyl standards. Environmental or health impact assessments for areas affected by DU munitions should therefore take into account the presence of respiratory UO2, U3O8 and even UO3 particles, their corresponding weathering rates and the subsequent mobilisation of U from oxidized DU particles. (C) 2004 Elsevier Ltd. All rights reserved.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.31
DOI: 10.1016/J.JENVAD.2004.04.001
|
|
|
“Polycapillary X-ray optics”. Gao N, Janssens K page 89 (2004).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Preface”. Janssens K, Van Grieken R page xxvii-xxviii (2004).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Provenance analysis of glass artefacts”. Gratuze B, Janssens K page 663 (2004).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Simulation of poly-capillary lenses for coherent and partially coherent x-rays”. Vincze L, Kukhlevsky SV, Janssens K, Proceedings of the Society of Photo-optical Instrumentation Engineers
T2 –, Conference on Advances in Computational Methods for X-Ray and Neutron, Optics, AUG 03-05, 2004, Denver, CO , 81 (2004). http://doi.org/10.1117/12.560740
Abstract: The intensity distributions of the coherent and partially coherent x-rays passed through a poly-capillary lens have been computed at the focal plane. The computations showed that at the appropriate experimental conditions the interference phenomenon does affect the intensity distribution. In the case of the coherent input radiation with the photon energy of 0.1 keV, the interference fringes were observed, while the non-coherent x-ray radiation produced no interference-like intensity distributions.
Keywords: P1 Proceeding; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Times cited: 6
DOI: 10.1117/12.560740
|
|
|
“Spread of façon-de-Venise glassmaking through central and western Europe”. Åmit Å, Janssens K, Schalm O, Kos M, Nuclear instruments and methods in physics research B 213, 717 (2004). http://doi.org/10.1016/S0168-583X903)01691-4
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0168-583X903)01691-4
|
|
|
“X-ray based methods of analysis”. Janssens K page 129 (2004).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Compositional analysis of 17-18th century archaeological glass fragments, excavated in Mechelen, Belgium: comparison with data from neighboring cities in the Low Countries”. van der Linden V, Bultinck E, de Ruytter J, Schalm O, Janssens K, Devos W, Tiri W, Nuclear instruments and methods in physics research: B: beam interactions with materials and atoms 239, 100 (2005). http://doi.org/10.1016/j.nimb.2005.06.219
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.109
Times cited: 15
DOI: 10.1016/j.nimb.2005.06.219
|
|
|
“Enamels in stained-glass windows : preparation, chemical composition, microstructure and causes of deterioration”. Caen J, Schalm O, van der Snickt G, van der Linden V, Frederickx P, Schryvers D, Janssens K, Cornelis E, van Dyck D, Schreiner M, , 121 (2005)
Keywords: P3 Proceeding; Art; Electron microscopy for materials research (EMAT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Vision lab
|
|
|
“Analysis of façon-de-Venise glass originating from Central and Western Europe”. Šmit Ž, Janssens K, Schalm O, Kos M page 165 (2005).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Black glass vessels and jewellery in Belgium : production, context analysis, chronology and use”. Cosyns P, Janssens K, Vanderlinden V, Schalm O, (2005)
Keywords: P3 Proceeding; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Characterization of carcinogenic Ni-rich dust particles by scanning micro-XRF/XRD at BL L”. de Nolf W, Janssens K, Rickers K (2005).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Characterization of uranium and plutonium containing particles originating from the nuclear weapons accident in Thule, Greenland, 1968”. Lind OC, Salbu B, Janssens K, Proost K, Dahlgaard H, Journal of environmental radioactivity 81, 21 (2005). http://doi.org/10.1016/J.JENVRAD.2004.10.013
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 2.31
Times cited: 37
DOI: 10.1016/J.JENVRAD.2004.10.013
|
|
|
“Composition of 13-17th century glass from non-figurative windows in secular buildings excavated in Belgium”. Schalm O, Wouters H, Janssens K, (2005)
Keywords: P3 Proceeding; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Confocal micro-XRF study of element distribution of a uranium enriched tertiary sediment”. Janssens K, Denecke M, Rothe J, Simon R page 13 (2005).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Confocal micrometer-scale X-ray fluorescence and X-ray absorption fine structure studies of uranium speciation in a tertiary sediment from a waste disposal natural analogue site”. Denecke MA, Janssens K, Proost K, Rothe J, Noseck U, Environmental science and technology 39, 2049 (2005). http://doi.org/10.1021/ES048644K
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 6.198
Times cited: 47
DOI: 10.1021/ES048644K
|
|
|
“Copper stabilization by zeolite synthesis in polluted soils treated with coal fly ash”. Terzano R, Spagnuolo M, Medici L, Vekemans B, Vincze L, Janssens K, Ruggiero P, Environmental science and technology 39, 6280 (2005). http://doi.org/10.1021/ES050079D
Abstract: This study deals with the process of zeolite formation in an agricultural soil artificially polluted by high amounts of Cu (15 mg of Cu/g of soil dry weight) and treated with fused coal fly ash at 30 and 60 degrees C and how this process affects the mobility and availability of the metal. As a consequence of the treatment, the amount of dissolved Cu, and thus its mobility, was strongly reduced, and the percentage of the metal stabilized in the solid phase increased over time, reaching values of 30% at 30 degrees C and 40% at 60 degrees C. The physicochemical phenomena responsible for Cu stabilization in the solid phase have been evaluated by EDTA sequential extractions and synchrotron radiation based X-ray microanalytical techniques. These techniques were used for the visualization of the spatial distribution and the speciation of Cu in and/or on the neo-formed zeolite particles. In particular, micro XRF (X-ray fluorescence) tomography showed direct evidence that Cu can be entrapped as clusters inside the porous zeolitic structures while,mu-XANES (X-ray absorption near edge structure) spectroscopy determinations revealed Cu to be present mainly as Cu(II) hydroxide and Cu(II) oxide. The reported results could be useful as a basic knowledge for planning new technologies for the on site physicochemical stabilization of heavy metals in heavily polluted soils.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 6.198
Times cited: 39
DOI: 10.1021/ES050079D
|
|
|
Van Grieken R, Janssens K (2005) Cultural heritage conservation and environmental impact assessment by non-destructive testing and micro-analysis. 336 p
Keywords: ME2 Book as editor or co-editor; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Estimation of relative Fe2+ and Fe3+ contents of original manuscript fragments by means of μ-XANES and Mössbauer spectrometry”. Janssens K, Vekemans B, Rouchon-Quillet V (2005).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“In-vivo 3D mapping and local speciation of Se compounds in roots and leaves of Allium Cepa”. Janssens K, Proost K, Wysocka A, Bulska E, Wierzbicka M (2005).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Investigation of the chemical state and 3D distribution of Mn in corroded glass fragments”. Proost K, Schalm O, Janssens K, Van Dyck D (2005).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Vision lab
|
|
|
“Microanalytical characterization of surface decoration in Majolica pottery”. Padilla R, Schalm O, Janssens K, Arrazcaeta R, van Espen P, Analytica chimica acta 535, 201 (2005). http://doi.org/10.1016/J.ACA.2004.11.082
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
Impact Factor: 4.95
Times cited: 20
DOI: 10.1016/J.ACA.2004.11.082
|
|
|
“Novel quantitative procedures for in-situ X-ray fluorescence analysis”. Van Grieken R, Janssens K, van Espen P, Injuk J, Padilla R, Vittiglio G, Potgieter JH page 45 (2005).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
|
|
|
“Preface”. Van Grieken R, Janssens K page vii-viii (2005).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Resonant backward scattering of light by a subwavelength metallic slit with two open sides”. Kukhlevsky SV, Mechler M, Csapó, L, Janssens K, Samek O, Physical review : B : condensed matter and materials physics 72, 165421 (2005). http://doi.org/10.1103/PHYSREVB.72.165421
Abstract: The backward scattering of TM-polarized light by a two-side-open subwavelength slit in a metal film is analyzed. We show that the reflection coefficient versus wavelength possesses a Fabry-Perot-like dependence that is similar to the anomalous behavior of transmission reported in the study [Y. Takakura, Phys. Rev. Lett. 86, 5601 (2001)]. The open slit totally reflects the light at the near-to-resonance wavelengths. In addition, we show that the interference of incident and resonantly backward-scattered light produces in the near-field diffraction zone a spatially localized wave whose intensity is 10103 times greater than the incident wave, but one order of magnitude smaller than the intracavity intensity. The amplitude and phase of the resonant wave at the slit entrance and exit are different from that of a Fabry-Perot cavity.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.836
Times cited: 7
DOI: 10.1103/PHYSREVB.72.165421
|
|
|
“Semiempirical approach for standardless calibration in µ-XRF spectrometry using capillary lenses”. Padilla R, van Espen P, Abrahantes A, Janssens K, X-ray spectrometry 34, 19 (2005). http://doi.org/10.1002/XRS.781
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
Impact Factor: 1.298
Times cited: 23
DOI: 10.1002/XRS.781
|
|
|
“A survey of the recent use of x-ray beam methods for non-destructive investigations in the cultural heritage sector”. Janssens K page 265 (2005).
Keywords: H3 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Trace element fingerprinting of façon-de-Venise glass”. Šmit Ž, Bulska E, Janssens K, Bulska E, Wagner B, Kos M, Lazar I, Nuclear instruments and methods in physics research: B: beam interactions with materials and atoms 239, 94 (2005). http://doi.org/10.1016/J.NIMB.2005.06.182
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 1.109
Times cited: 27
DOI: 10.1016/J.NIMB.2005.06.182
|
|