|
“Modeling of chemical processes in the low pressure capacitive radio frequency discharges in a mixture of Ar/C2H2”. Ariskin DA, Schweigert IV, Alexandrov AL, Bogaerts A, Peeters FM, Journal of applied physics 105, 063305 (2009). http://doi.org/10.1063/1.3095760
Abstract: We study the properties of a capacitive 13.56 MHz discharge with a mixture of Ar/C<sub>2</sub>H<sub>2</sub> taking into account the plasmochemistry and growth of heavy hydrocarbons. A hybrid model was developed to combine the kinetic description for electron motion and the fluid approach for negative and positive ion transports and plasmochemical processes. A significant change in plasma parameters related to injection of 5.8% portion of acetylene in argon was observed and analyzed. We found that the electronegativity of the mixture is about 30%. The densities of negatively and positively charged heavy hydrocarbons are sufficiently large to be precursors for the formation of nanoparticles in the discharge volume.
Keywords: A1 Journal article; Condensed Matter Theory (CMT); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.068
Times cited: 21
DOI: 10.1063/1.3095760
|
|
|
“Three-dimensional chemical characterization of complex silver halide microcrystals by scanning ion microprobe mass analysis”. Verlinden G, Janssens G, Gijbels R, van Espen P, Geuens I, Analytical chemistry 69, 3773 (1997). http://doi.org/10.1021/ac970010r
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); Chemometrics (Mitac 3)
Impact Factor: 6.32
Times cited: 6
DOI: 10.1021/ac970010r
|
|
|
“Catalyzed growth of encapsulated carbyne”. Khalilov U, Vets C, Neyts EC, Carbon 153, 1 (2019). http://doi.org/10.1016/j.carbon.2019.06.110
Abstract: Carbyne is a novel material of current interest in nanotechnology. As is typically the case for nanomaterials, the growth process determines the resulting properties. While endohedral carbyne has been successfully synthesized, its catalyst and feedstock-dependent growth mechanism is still elusive. We here study the nucleation and growth mechanism of different carbon chains in a Ni-containing double walled carbon nanotube using classical molecular dynamics simulations and first-principles calculations. We find that the understanding the competitive role of the metal catalyst and the hydrocarbon is important to control the growth of 1-dimensional carbon chains, including Ni or H-terminated carbyne. Also, we find that the electronic property of the Ni-terminated carbyne can be tuned by steering the H concentration along the chain. These results suggest catalyst-containing carbon nanotubes as a possible synthesis route for carbyne formation.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 6.337
DOI: 10.1016/j.carbon.2019.06.110
|
|
|
“Grain size tuning of nanocrystalline chemical vapor deposited diamond by continuous electrical bias growth : experimental and theoretical study”. Mortet V, Zhang L, Eckert M, D'Haen J, Soltani A, Moreau M, Troadec D, Neyts E, De Jaeger JC, Verbeeck J, Bogaerts A, Van Tendeloo G, Haenen K, Wagner P, Physica status solidi : A : applications and materials science 209, 1675 (2012). http://doi.org/10.1002/pssa.201200581
Abstract: In this work, a detailed structural and spectroscopic study of nanocrystalline diamond (NCD) thin films grown by a continuous bias assisted CVD growth technique is reported. This technique allows the tuning of grain size and phase purity in the deposited material. The crystalline properties of the films are characterized by SEM, TEM, EELS, and Raman spectroscopy. A clear improvement of the crystalline structure of the nanograined diamond film is observed for low negative bias voltages, while high bias voltages lead to thin films consisting of diamond grains of only ∼10 nm nanometer in size, showing remarkable similarities with so-called ultrananocrystalline diamond. These layers arecharacterized by an increasing amount of sp2-bonded carbon content of the matrix in which the diamond grains are embedded. Classical molecular dynamics simulations support the observed experimental data, giving insight in the underlying mechanism for the observed increase in deposition rate with bias voltage. Furthermore, a high atomic concentration of hydrogen has been determined in these films. Finally, Raman scattering analyses confirm that the Raman line observed at ∼1150 cm−1 cannot be attributed to trans-poly-acetylene, which continues to be reported in literature, reassigning it to a deformation mode of CHx bonds in NCD.
Keywords: A1 Journal article; Electron microscopy for materials research (EMAT); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.775
Times cited: 31
DOI: 10.1002/pssa.201200581
|
|
|
“Improving the Conversion and Energy Efficiency of Carbon Dioxide Splitting in a Zirconia-Packed Dielectric Barrier Discharge Reactor”. van Laer K, Bogaerts A, Energy technology 3, 1038 (2015). http://doi.org/10.1002/ente.201500127
Abstract: The use of plasma technology for CO2 splitting is gaining increasing interest, but one of the major obstacles to date for industrial implementation is the considerable energy cost. We demonstrate that the introduction of a packing of dielectric zirconia (ZrO2) beads into a dielectric barrier discharge (DBD) plasma reactor can enhance the CO2 conversion and energy efficiency up to a factor 1.9 and 2.2, respectively, compared to that in a normal (unpacked) DBD reactor. We obtained a maximum conversion of 42 % and a maximum energy efficiency of 9.6 %. However, it is the ability of the packing to almost double both the conversion and the energy efficiency simultaneously at certain input parameters that makes it very promising. The improved conversion and energy efficiency can be explained by the higher values of the local electric field and electron energy near the contact points of the beads and the lower breakdown voltage, demonstrated by 2 D fluid modeling.
Keywords: A1 Journal article; Engineering sciences. Technology; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.789
Times cited: 59
DOI: 10.1002/ente.201500127
|
|
|
“Investigation of Ag, Ag2S and Ag(Br,I) small particles by HREM and AEM”. Oleshko V, Schryvers D, Gijbels R, Jacob W s.l., page 293 (1998).
Keywords: H3 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Glow discharge optical spectroscopy and mass spectrometry”. Bogaerts A John Wiley & Sons, Chichester, page 1 (2016).
Abstract: Atomic Spectroscopy Optical (atomic absorption spectroscopy, AAS; atomic emission spectroscopy, AES; atomic fluorescence spectroscopy, AFS; and optogalvanic spectroscopy) and mass spectrometric (magnetic sector, quadrupole mass analyzer, QMA; quadrupole ion trap, QIT; Fourier transform ion cyclotron resonance, FTICR; and time-of-flight, TOF) instrumentation are well suited for coupling to the glow discharge (GD). The GD is a relatively simple device. A potential gradient (500–1500 V) is applied between an anode and a cathode. In most cases, the sample is also the cathode. A noble gas (mostly Ar) is introduced into the discharge region before power initiation. When a potential is applied, electrons are accelerated toward the anode. As these electrons accelerate, they collide with gas atoms. A fraction of these collisions are of sufficient energy to remove an electron from a support gas atom, forming an ion. These ions are, in turn, accelerated toward the cathode. These ions impinge on the surface of the cathode, sputtering sample atoms from the surface. Sputtered atoms that do not redeposit on the surface diffuse into the excitation/ionization regions of the plasma where they can undergo excitation and/or ionization via a number of collisional processes, and the photons or ions created in this way can be detected with optical emission spectroscopy or mass spectrometry. GD sources offer a number of distinct advantages that make them well suited for specific types of analyses. These sources afford direct analysis of solid samples, thus minimizing the sample preparation required for analysis. The nature of the plasma also provides mutually exclusive atomization and excitation processes that help to minimize the matrix effects that plague so many other elemental techniques. In recent years, there is also increasing interest for using GD sources for liquid and gas analyses. In this article, first, the principles of operation of the GD plasma are reviewed, with an emphasis on how those principles relate to optical spectroscopy and mass spectrometry. Basic applications of the GD techniques are considered next. These include bulk analysis, surface analysis, and the analysis of solution and gaseous samples. The requirements necessary to obtain optical information are addressed following the analytical applications. This article focuses on the instrumentation needed to make optical measurements using the GD as an atomization/excitation source. Finally, mass spectrometric instrumentation and interfaces are addressed as they pertain to the use of a GD plasma as an ion source. GD sources provide analytically useful gas-phase species from solid samples. These sources can be interfaced with a variety of spectroscopic and spectrometric instruments for both quantitative and qualitative analyses.
Keywords: H1 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Analysis and comparison of the co2 and co dielectric barrier discharge solid products”. Belov I, Paulussen S, Bogaerts A, Hakone Xv: International Symposium On High Pressure Low Temperature Plasma Chemistry: With Joint Cost Td1208 Workshop: Non-equilibrium Plasmas With Liquids For Water And Surface Treatment (2016)
Abstract: The CO and CO2 Dielectric Barrier Discharges (DBD) and their solid products were analyzed keeping similar energy input regimes. Gas chromatography analysis revealed the presence of CO2, CO and O-2 mixture in the exhaust of the CO2 DBD, while no O-2 was found when CO was used as a feed gas. It was shown that the C-2 Swan lines observed with optical emission spectroscopy were distinct in the CO plasma while they were not observed in the CO2 emission spectrum. Also the solid products of the plasmas exhibited remarkable differences. Nanoparticles with a diameter between10 and 300 nm, composed of Fe, O and C (Fe: O: C similar to 13: 50: 30) were produced by the CO2 DBD, while microscopic dendrite-like carbon structure (C: O similar to 73: 27) were formed in the CO plasma. The growth rate in the CO2 and CO DBDs was evaluated to be on the level of 0.15 mg/min and 15 mg/min, respectively. The difference of the CO and CO2 discharges and their products might be attributed to the oxygen content in the latter (6.4 mol.% O-2 in the exhaust) and subsequent etching of the carbonaceous film.
Keywords: P1 Proceeding; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“Plasma based co2 conversion: a combined modeling and experimental study”. Bogaerts A, Snoeckx R, Berthelot A, Heijkers S, Wang W, Sun S, Van Laer K, Ramakers M, Michielsen I, Uytdenhouwen Y, Meynen V, Cool P, Hakone Xv: International Symposium On High Pressure Low Temperature Plasma Chemistry: With Joint Cost Td1208 Workshop: Non-equilibrium Plasmas With Liquids For Water And Surface Treatment (2016)
Abstract: In recent years there is increased interest in plasma-based CO2 conversion. Several plasma setups are being investigated for this purpose, but the most commonly used ones are a dielectric barrier discharge (DBD), a microwave (MW) plasma and a gliding arc (GA) reactor. In this proceedings paper, we will show results from our experiments in a (packed bed) DBD reactor and in a vortex-flow GA reactor, as well as from our model calculations for the detailed plasma chemistry in a DBD, MW and GA, for pure CO2 as well as mixtures of CO2 with N-2, CH4 and H2O.
Keywords: P1 Proceeding; Laboratory of adsorption and catalysis (LADCA); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
Grü,newald L, Chezganov D, De Meyer R, Orekhov A, Van Aert S, Bogaerts A, Bals S, Verbeeck J (2023) Supplementary Information for “In-situ Plasma Studies using a Direct Current Microplasma in a Scanning Electron Microscope”
Abstract: Supplementary information for the article “In-situ Plasma Studies using a Direct Current Microplasma in a Scanning Electron Microscope” containing the videos of in-situ SEM imaging (mp4 files), raw data/images, and Jupyter notebooks (ipynb files) for data treatment and plots. Link to the preprint: https://doi.org/10.48550/arXiv.2308.15123 Explanation of the data files can be found in the Information.pdf file. The Videos folder contains the in-situ SEM image series mentioned in the paper. If there are any questions/bugs, feel free to contact me at lukas.grunewaldatuantwerpen.be
Keywords: Dataset; Engineering sciences. Technology; Electron microscopy for materials research (EMAT); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
DOI: 10.5281/ZENODO.8042030
|
|
|
“Computer simulations of laser ablation, plume expansion and plasma formation”. Bogaerts A, Aghaei M, Autrique D, Lindner H, Chen Z, Wendelen W Trans Tech, Aedermannsdorf, page 1 (2011).
Keywords: H1 Book chapter; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 8
DOI: 10.4028/www.scientific.net/AMR.227.1
|
|
|
“Synergism of the initial stage of removal of dielectric materials during electrical erosion processing in electrolytes”. Zaripov AA, Khalilov UB, Ashurov KB, Surface engineering and applied electrochemistry 59, 712 (2023). http://doi.org/10.3103/S1068375523060194
Abstract: Ceramics and composites, many of whose physicochemical properties significantly exceed similar properties of metals and their alloys, are processed qualitatively mainly by the electroerosion method. Despite the existing works, the mechanism of the initial stage of the removal of materials has not yet been identified. For a comprehensive understanding of the mechanism of the removal of dielectrics, a new model is proposed based on the experimental results obtained on an improved electroerosion installation. It was revealed that the initial stage of the removal of a dielectric material consists of three successive stages that are associated with the synergistic effect on the process of the anionic group of electrolytes, plasma flare, and the cavitation shock. This makes it possible to better understand the mechanism of the removal of composite and ceramic materials, which should contribute to ensuring the machinability of those materials and their wide use in promising technologies.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
DOI: 10.3103/S1068375523060194
|
|
|
“The plasma treatment unit : an attempt to standardize cold plasma treatment for defined biological effects”. Fridman A, Lin A, Miller V, Bekeschus S, Wende K, Weltmann K-D, Plasma medicine 8, 195 (2018). http://doi.org/10.1615/PLASMAMED.2018026881
Abstract: Plasma bioscience and medicine are both rapidly growing fields. Their aim is to utilize cold physical plasmas for desired biological outcomes in medicine, biotechnology, agriculture, and general hygienic purposes. Great success has been achieved in many applications with individually designed plasma sources and plasma parameters. Although lab and application-specific tuning of plasmas is a great advantage of this technology, standardized units to define plasma treatments are required to facilitate comparison of the effects found by different researchers who do not use the same plasma sources. By drawing conclusions from over a century of plasma biomedical research, we propose that all researchers adopt the use of a standardized value, the plasma treatment unit (PTU), to describe the biological effects of different cold plasma sources and treatment regimens. It quantifies a key plasma effector in biological systems as an indicator and may provide the foundation for an analogous and clinically relevant unit in the future.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
DOI: 10.1615/PLASMAMED.2018026881
|
|
|
“Nanosecond-pulsed dielectric barrier dischargeinduced antitumor effects propagate through depth of tissue via intracellular signaling”. Ranieri P, Shrivastav R, Wang M, Lin A, Fridman G, Fridman AA, Han L-H, Miller V, Plasma medicine 7, 283 (2017). http://doi.org/10.1615/PLASMAMED.2017019883
Abstract: Studies using xenograft mouse models have shown that plasma applied to the skin overlying tumors results in tumor shrinkage. Plasma is considered a nonpenetrating treatment; however, these studies demonstrate plasma effects that occur beyond the postulated depth of physical penetration of plasma components. The present study examines the propagation of plasma effects through a tissue model using three-dimensional, cell-laden extracellular matrices (ECMs). These ECMs are used as barriers against direct plasma penetration. By placing them onto a monolayer of target cancer cells to create an in-vitro analog to in-vivo studies, we distinguished between cellular effects from direct plasma exposure and cellular effects due to cell-to-cell signaling stimulated by plasma. We show that nanosecond-pulsed dielectric barrier discharge plasma treatment applied atop an acellular barrier impedes the externalization of calreticulin (CRT) in the target cells. In contrast, when a barrier is populated with cells, CRT externalization is restored. Thus, we demonstrate that plasma components stimulate signaling among cells embedded in the barrier to transfer plasma effects to the target cells.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
DOI: 10.1615/PLASMAMED.2017019883
|
|
|
“Immune cells enhance selectivity of nanosecond-pulsed DBD plasma against tumor cells”. Lin A, Truong B, Fridman G, Friedman AA, Miller V, Plasma medicine 7, 85 (2017). http://doi.org/10.1615/PLASMAMED.2017019666
Abstract: Cancer immunotherapy is a promising strategy that engages the patient's immune system to kill cancer cells selectively while sparing normal tissue. Treatment of macrophages with a nanosecond-pulsed dielectric barrier discharge directly enhanced their cytotoxic activity against tumor cells but not normal cells. These results underscore the clinical potential of plasma for cancer immunotherapy.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
DOI: 10.1615/PLASMAMED.2017019666
|
|
|
“Apical application of nanosecond-pulsed dielectric barrier discharge plasma causes the basolateral release of adenosine triphosphate as a damage-associated molecular pattern from polarized HaCaT cells”. Truong B, Siegert K, Lin A, Miller V, Krebs FC, Plasma medicine 7, 117 (2017). http://doi.org/10.1615/PLASMAMED.2017019120
Abstract: Promising biomedical uses for nonthermal plasma (NTP) in the fields of regenerative medicine, cancer therapy, and vaccine delivery involve the noninvasive application of uniform nonequilibrium plasma (including dielectric barrier discharge plasma) to living skin. Whereas most investigations have focused on achieving desired therapeutic outcomes, fewer studies have examined the mechanisms and pathways by which epithelial cells respond to NTP exposure. Using a transwell apical-basolateral-chambered system to culture the human keratinocyte HaCaT cell line, in vitro experiments were performed to demonstrate the effects of nanosecond-pulsed dielectric barrier discharge (nsDBD) plasma on polarized epithelial cell viability, monolayer permeability, intracellular oxidative stress, and the release of adenosine triphosphate (ATP). Application of nsDBD plasma at 60 Hz or below had minimal or no effect on HaCaT monolayer viability or permeability. nsDBD plasma exposure did, however, result in frequency-dependent reductions in intracellular glutathione (indicating direct induction of oxidative stress by nsDBD plasma) and increased extracellular ATP concentrations in the ba-solateral (subepithelial) media, which are indicators of cellular stress and an NTP-induced inflammatory response. These studies provide new insights into nsDBD plasma-induced inflammation and local innate immune responses initiated by polarized epithelial tissues.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
DOI: 10.1615/PLASMAMED.2017019120
|
|
|
“Numerical modeling for a better understanding of gas discharge plasmas”. Bogaerts A, de Bleecker K, Georgieva V, Herrebout D, Kolev I, Madani M, Neyts E, High temperature material processes 9, 321 (2005). http://doi.org/10.1615/HighTempMatProc.v9.i3.10
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 1
DOI: 10.1615/HighTempMatProc.v9.i3.10
|
|
|
“Modeling PECVD growth of nanostructured carbon materials”. Neyts E, Bogaerts A, van de Sanden MCM, High temperature material processes 13, 399 (2009). http://doi.org/10.1615/HighTempMatProc.v13.i3-4.120
Abstract: We present here some of our modeling efforts for PECVD growth of nanostructured carbon materials with focus on amorphous hydrogenated carbon. Experimental data from an expanding thermal plasma setup were used as input for the simulations. Attention was focused both on the film growth mechanism, as well as on the hydrocarbon reaction mechanisms during growth of the films. It is found that the reaction mechanisms and sticking coefficients are dependent on the specific surface sites, and the structural properties of the growth radicals. The film growth results are in correspondence with the experiment. Furthermore, it is found that thin a-C:H films can be densified using an additional H-flux towards the substrate.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
DOI: 10.1615/HighTempMatProc.v13.i3-4.120
|
|
|
“Modeling of the synthesis and subsequent growth of nanoparticles in dusty plasmas”. de Bleecker K, Bogaerts A, High temperature material processes 11, 21 (2007). http://doi.org/10.1615/HighTempMatProc.v11.i1.20
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
DOI: 10.1615/HighTempMatProc.v11.i1.20
|
|
|
“Characterization of nano-crystalline diamond films grown under continuous DC bias during plasma enhanced chemical vapor deposition”. Mortet V, Zhang L, Echert M, Soltani A, d' Haen J, Douheret O, Moreau M, Osswald S, Neyts E, Troadec D, Wagner P, Bogaerts A, Van Tendeloo G, Haenen K, Materials Research Society symposium proceedings (2009). http://doi.org/10.1557/PROC-1203-J05-03
Abstract: Nanocrystalline diamond films have generated much interested due to their diamond-like properties and low surface roughness. Several techniques have been used to obtain a high re-nucleation rate, such as hydrogen poor or high methane concentration plasmas. In this work, the properties of nano-diamond films grown on silicon substrates using a continuous DC bias voltage during the complete duration of growth are studied. Subsequently, the layers were characterised by several morphological, structural and optical techniques. Besides a thorough investigation of the surface structure, using SEM and AFM, special attention was paid to the bulk structure of the films. The application of FTIR, XRD, multi wavelength Raman spectroscopy, TEM and EELS yielded a detailed insight in important properties such as the amount of crystallinity, the hydrogen content and grain size. Although these films are smooth, they are under a considerable compressive stress. FTIR spectroscopy points to a high hydrogen content in the films, while Raman and EELS indicate a high concentration of sp2 carbon. TEM and EELS show that these films consist of diamond nano-grains mixed with an amorphous sp2 bonded carbon, these results are consistent with the XRD and UV Raman spectroscopy data.
Keywords: A3 Journal article; Electron microscopy for materials research (EMAT); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
DOI: 10.1557/PROC-1203-J05-03
|
|
|
“Modeling of the plasma chemistry and plasmasurface interactions in reactive plasmas”. Bogaerts A, De Bie C, Eckert M, Georgieva V, Martens T, Neyts E, Tinck S, Pure and applied chemistry 82, 1283 (2010). http://doi.org/10.1351/PAC-CON-09-09-20
Abstract: In this paper, an overview is given of modeling activities going on in our research group, for describing the plasma chemistry and plasmasurface interactions in reactive plasmas. The plasma chemistry is calculated by a fluid approach or by hybrid Monte Carlo (MC)fluid modeling. An example of both is illustrated in the first part of the paper. The example of fluid modeling is given for a dielectric barrier discharge (DBD) in CH4/O2, to describe the partial oxidation of CH4 into value-added chemicals. The example of hybrid MCfluid modeling concerns an inductively coupled plasma (ICP) etch reactor in Ar/Cl2/O2, including also the description of the etch process. The second part of the paper deals with the treatment of plasmasurface interactions on the atomic level, with molecular dynamics (MD) simulations or a combination of MD and MC simulations.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 2.626
Times cited: 13
DOI: 10.1351/PAC-CON-09-09-20
|
|
|
“A new electrostatic transfer line for improved transmission in Fourier transform laser microprobe mass spectrometry with external ion source”. van Vaeck L, van Espen P, Gijbels R, Baykut G, Laukien FH, European mass spectrometry 6, 277 (2000). http://doi.org/10.1255/ejms.342
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); Chemometrics (Mitac 3)
Times cited: 10
DOI: 10.1255/ejms.342
|
|
|
“Investigation of laser output power saturation in the He-Cu+ IR hollow cathode discharge laser by experiments and numerical modeling”. Bogaerts A, Gijbels R, Grozeva M, Sabotinov N, Physica scripta T105, 90 (2003). http://doi.org/10.1238/Physica.Topical.105a00090
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.28
DOI: 10.1238/Physica.Topical.105a00090
|
|
|
“Optical bistability and multistability in four-level systems”. Chen Z, Feng X, Xu Y, Yu MY, Physica scripta 68, 199 (2003). http://doi.org/10.1238/Physica.Regular.068a00199
Abstract: The optical behavior of a four-level system in a ring cavity driven by two coherent laser fields is studied. One laser field is treated as the incident field and the other the control field, respectively. It is found that there is optical transparency when the difference between the two frequency detunings of the incident and control fields from the corresponding atomic transition frequencies is zero. Optical bistability can be produced and controlled by increasing the magnitude of the frequency difference. The bistable hysteresis becomes larger when the frequency difference is increased. Further increase of the latter can lead to onset of multistability.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.28
Times cited: 8
DOI: 10.1238/Physica.Regular.068a00199
|
|
|
“Ground state configurations of two-dimensional plasma crystals under long-range attractive particle interaction force”. Chen Z, Kong M, Milošević, MV, Wu Y, Physica scripta 67, 439 (2003). http://doi.org/10.1238/Physica.Regular.067a00439
Keywords: A1 Journal article; Condensed Matter Theory (CMT); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.28
Times cited: 4
DOI: 10.1238/Physica.Regular.067a00439
|
|
|
“Long-distance channeling and focusing of lasers in plasmas”. Yuan X, Yu W, Yu MY, Chen ZY, Liu JR, Lu PX, Li RX, Qian LJ, Lu BD, Physica scripta 66, 381 (2002). http://doi.org/10.1238/Physica.Regular.066a00381
Abstract: The propagation of a short laser beam in plasma is investigated analytically Relativistic ponderomotive force and space charge effects are included, and an equation describing the evolution of the laser spot size is derived. It is shown that self-consistent electron cavitation can lead to self channelling and thus long-distance self-focusing of the laser. The condition for the latter to occur is given.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.28
Times cited: 2
DOI: 10.1238/Physica.Regular.066a00381
|
|
|
“Insights into the C Distribution in Si:C/Si:C:P and the Annealing Behavior of Si:C Layers”. Dhayalan SK, Nuytten T, Pourtois G, Simoen E, Pezzoli F, Cinquanta E, Bonera E, Loo R, Rosseel E, Hikavyy A, Shimura Y, Vandervorst W, ECS journal of solid state science and technology 8, P209 (2019). http://doi.org/10.1149/2.0181903JSS
Abstract: Si:C and Si:C:P alloys are potential candidates for source-drain stressor applications in n-type Fin Field Effect Transistors (FinFETs). Increasing the C content to achieve high strain results in the arrangement of C atoms as third nearest neighbors (3nn) in the Si: C lattice. During thermal annealing, the presence of C atoms as 3nn may promote clustering at the interstitial sites, causing loss of stress. The concentration of C atoms as 3nn is reduced by the incorporation of a small amount of Ge atoms during the growth, whereas in-situ P doping does not influence this 3nn distribution [J Solid State Sci. Technol vol 6, p 755, 2017]. Small amounts of Ge are provided during low temperature selective epitaxial growth scheme, which are based on cyclic deposition and etching (CDE). In this work, we aim to provide physical insights into the aforementioned phenomena, to understand the behavior of 3nn C atoms and the types of defects that are formed in the annealed Si: C films. Using ab-initio simulations, the Ge-C interaction in the Si matrix is investigated and this insight is used to explain how the Ge incorporation leads to a reduced 3nn distribution of the C atoms. The interaction between C and P in the Si: C: P films is also investigated to explain why the P incorporation has not led to a reduction in the 3nn distribution. We then report on the Raman characterization of Si: C layers subjected to post epi annealing. As the penetration depth of the laser is dependent on the wavelength, Raman measurements at two different wavelengths enable us to probe the depth distribution of 3nn C atoms after applying different annealing conditions. We observed a homogeneous loss in 3nn C throughout the layer. Whereas in the kinematic modeling of high resolution X-ray diffraction spectra, a gradient in the substitutional C loss was observed close to the epitaxial layer/substrate interface. This gradient can be due to the out diffusion of C atoms into the Si substrate or to the formation of interstitial C clusters, which cannot be distinguished in HR-XRD. Deep Level Transient Spectroscopy indicated that the prominent out-diffusing species was interstitial CO complex while the interstitial C defects were also prevalent in the epi layer. (c) 2019 The Electrochemical Society.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.787
DOI: 10.1149/2.0181903JSS
|
|
|
“Study of the intrinsic limitations of the contact resistance of metal/semiconductor interfaces through atomistic simulations”. Dabral A, Pourtois G, Sankaran K, Magnus W, Yu H, de de Meux AJ, Lu AKA, Clima S, Stokbro K, Schaekers M, Collaert N, Horiguchi N, Houssa M, ECS journal of solid state science and technology 7, N73 (2018). http://doi.org/10.1149/2.0041806JSS
Abstract: In this contribution, we report a fundamental study of the factors that set the contact resistivity between metals and highly doped n-type 2D and 3D semiconductors. We investigate the case of n-type doped Si contacted with amorphous TiSi combining first principles calculations with Non-Equilibrium Green functions transport simulations. The evolution of the intrinsic contact resistivity with the doping concentration is found to saturate at similar to 2 x 10(-10) Omega.cm(2) for the case of TiSi and imposes an intrinsic limit to the ultimate contact resistance achievable for n-doped Silamorphous-TiSi (aTiSi). The limit arises from the intrinsic properties of the semiconductors and of the metals such as their electron effective masses and Fermi energies. We illustrate that, in this regime, contacting heavy electron effective mass metals with semiconductor helps reducing the interface intrinsic contact resistivity. This observation seems to hold true regardless of the 3D character of the semiconductor, as illustrated for the case of three 2D semiconducting materials, namely MoS2, ZrS2 and HfS2. (C) The Author(s) 2018. Published by ECS.
Keywords: A1 Journal article; Condensed Matter Theory (CMT); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.787
Times cited: 2
DOI: 10.1149/2.0041806JSS
|
|
|
“Asymmetry and switching phenomenology in TiN\ (Al2O3) \ HfO2 \ Hf systems”. Goux L, Fantini A, Govoreanu B, Kar G, Clima S, Chen Y-Y, Degraeve R, Wouters DJ, Pourtois G, Jurczak M, ECS solid state letters 1, 63 (2012). http://doi.org/10.1149/2.003204ssl
Abstract: In this letter, we address the bipolar resistive switching phenomenology in scaled TiN\HfO2\Hf cells. By means of stack engineering using a thin Al2O3 layer inserted either at the TiN\HfO2 or at the Hf\HfO2 interface, we demonstrate that the reset operation takes place close to the TiNanode. Due to the increase of the oxygen-vacancy profile from the TiN to the Hf interface, the filament-confining and wide band-gap Al2O3 layer should indeed be engineered at the interface with the TiN electrode in order to further improve the switching control and to allow reaching larger state resistances. (C) 2012 The Electrochemical Society. [DOI: 10.1149/2.003204ssl] All rights reserved.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 1.184
Times cited: 11
DOI: 10.1149/2.003204ssl
|
|
|
“Modeling the growth of SWNTs and graphene on the atomic scale”. Neyts EC, Bogaerts A, ECS transactions 45, 73 (2012). http://doi.org/10.1149/1.3700454
Abstract: The possibility of application of nanomaterials is determined by our ability to control the properties of the materials, which are ultimately determined by their structure and hence their growth processes. We employ hybrid molecular dynamics / Monte Carlo (MD/MC) simulations to explore the growth of SWNTs and graphene on nickel as a catalyst, with the specific goal of unraveling the growth mechanisms. While the general observations are in agreement with the literature, we find a number of interesting phenomena to be operative which are crucial for the growth, and which are not accessible by MD simulations alone due to the associated time scale. Specifically, we observe metal mediated healing and restructuring processes to take place, reorganizing the carbon network during the initial nucleation step. In the case of carbon nanotube growth, this leads to the growth of tubes with a determinable chirality. In the case of graphene formation, we find that graphene is only formed at temperatures above 700 K. These results are of importance for understanding the growth mechanisms of these carbon nanomaterials on the fundamental level.
Keywords: A1 Journal article; Engineering sciences. Technology; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 2
DOI: 10.1149/1.3700454
|
|