“Analogy between one-dimensional chain models and graphene”. Matulis A, Peeters FM, American journal of physics 77, 595 (2009). http://doi.org/10.1119/1.3127143
Abstract: The electron and hole spectrum in single and bilayer graphene is derived from known one-dimensional models, and the relation between the spectrum and symmetry of the lattice is shown.
Keywords: A1 Journal article; Condensed Matter Theory (CMT)
Impact Factor: 1.069
Times cited: 11
DOI: 10.1119/1.3127143
|
|
|
“The magnetic Kronig-Penney model”. Ibrahim IS, Peeters FM, American journal of physics 63, 171 (1995). http://doi.org/10.1119/1.17977
Keywords: A1 Journal article; Condensed Matter Theory (CMT)
Impact Factor: 0.956
Times cited: 21
DOI: 10.1119/1.17977
|
|
|
Verhulst SL, de Backer J, Van Gaal L, de Backer W, Desager K (2008) Adenotonsillectomy as first-line treatment for sleep-disordered breathing in obese children. New York, 1399
Keywords: L1 Letter to the editor; Condensed Matter Theory (CMT); Laboratory Experimental Medicine and Pediatrics (LEMP)
Impact Factor: 13.204
|
|
|
“Parnaiba Basin shales (Northeast Brazil)”. Mabesoone JM, Farias CC, Van Grieken R, Duarte PJ, Delgado A, Freira EMP, Anais da Academia Brasileira de Ciências 57, 481 (1985)
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Charakterystyka i wpływ zanieczyszczeń, powietrza na eksponaty w muzeach”. Kontozova-Deutsch V, Deutsch F, Krata A, Van Grieken R, Análityka , 64 (2008)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Oszklenie ochronne i jego wpływ na średniowieczne okna witrazowe: z perspektywy chemii atmosfery: studium przypadku kaplica Sainte Chapelle w Paryzu”. Kontozova V, Godoi R, Krata A, Van Grieken R, Analityka , 20 (2007)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Laser ionization mass spectrometry for the characterization of solid materials”. van Vaeck L, van Roy W, Gijbels R, Analusis : chimie analytique, méthodes physiques d'analyse, composition de la matière 21, 53 (1993)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Times cited: 10
|
|
|
“Laser ionization mass-spectrometry for the characterization of solid materials”. van Vaeck L, Vanroy W, Gijbels R, Analusis : chimie analytique, méthodes physiques d'analyse, composition de la matière 20, S29 (1992)
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
|
|
|
“A Benzocaine‐Induced Local Near‐Surface pH Effect: Influence on the Accuracy of Voltammetric Cocaine Detection”. de Jong M, Sleegers N, Schram J, Daems D, Florea A, De Wael K, Analysis &, Sensing , anse.202000012 (2020). http://doi.org/10.1002/anse.202000012
Abstract: This work reports on a local induced near-surface pH effect (pHS), due to the presence of one analyte, leading to an influence or even suppression of redox signals of a second analyte present in solution. This concept and its impact on voltammetric sensing is illustrated by focusing on the detection of cocaine in the presence of the common adulterant benzocaine. An in-depth study on the occurring interference mechanism and why it occurs for benzocaine specifically and not for other adulterants was performed through the use of multiple electrochemical strategies. It was concluded that the potential shift and loss of intensity of the squarewave voltammetric cocaine signal in the presence of benzocaine was caused by a local pHS effect. A cathodic pretreatment strategy was developed to nonetheless allow accurate cocaine detection. The gathered insights are useful to explain unidentified phenomena involving compounds with properties similar to benzocaine in voltammetric electroanalysis.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1002/anse.202000012
|
|
|
“A message in the dust”. Jambers W, Van Grieken R, Analysis Europe , 25 (1996)
Keywords: A3 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|
|
“Reliability of copper dual damascene influenced by pre-clean”. Tokei Z, Lanckmans F, van den Bosch G, Van Hove M, Maex K, Bender H, Hens S, van Landuyt J, Analysis Of Integrated Circuits , 118 (2002). http://doi.org/10.1109/IPFA.2002.1025629
Keywords: P1 Proceeding; Electron microscopy for materials research (EMAT)
Times cited: 5
DOI: 10.1109/IPFA.2002.1025629
|
|
|
“Electrochemical Analysis of Speedball-like Polydrug Samples”. de Jong M, Florea A, Daems D, Van Loon J, Samyn N, De Wael K, Analyst (2020). http://doi.org/10.1039/D0AN01097A
Abstract: Increasing global production, trafficking and consumption of drugs of abuse cause an emerging threat to people’s health and safety. Electrochemical approaches have proven to be useful for on-site analysis of drugs of abuse. However, few attention has been focused on the analysis of polydrug samples, despite these samples causing severe health concerns, certainly when stimulants and depressants are combined, as is the case for Speedball, a mixture of cocaine and heroin. In this work, we provide solutions for the selective detection of cocaine (stimulant) in polydrug samples adulterated with heroin and codeine (depressants). The presence of either one of these compounds in cocaine street samples leads to an overlap with the cocaine signal in square-wave voltammetry measurements at unmodified carbon screen-printed electrodes, leading to inconclusive screening results in the field. The provided solutions to this problem consist of two parallel approaches: (i) cathodic pretreatment of the carbon screen-printed electrode surface prior to measurement in both alkaline and neutral conditions; (ii) electropolymerization of orthophenylenediamine on graphene modified carbon screen-printed electrodes prior to measurement in neutral conditions. Both strategies allow simultaneous detection of cocaine and heroin in speedball samples as well as simultaneous detection of cocaine and codeine. Implementing these strategies in portable devices holds great potential for significantly improved accuracy of on-site cocaine screening in polydrug samples.
Keywords: A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Product development
Impact Factor: 4.2
DOI: 10.1039/D0AN01097A
|
|
|
“Gold-sputtered microelectrodes with built-in gold reference and counter electrodes for electrochemical DNA detection”. Thiruvottriyur Shanmugam S, Trashin S, De Wael K, Analyst (2020). http://doi.org/10.1039/D0AN01387K
Abstract: Gold-sputtered microelectrodes with built-in gold reference and counter electrodes represent a promising platform for the development of disposable DNA sensors. Pretreating gold electrode surfaces and immobilization of DNA thereon is commonly employed in biosensing applications. However, with no scientific or practical guidelines to prepare a DNA sensor using these miniature gold-sputtered microelectrodes, cleaning and immobilization steps need to be systematically optimized and updated. In this work, we present efficient cleaning and modification of miniaturized gold-sputtered microelectrodes with thiolated DNA probes for DNA detection. Additional discussions on subtleties and nuances involved at each stage of pretreating and modifying gold-sputtered microelectrodes are included to present a robust, well-founded protocol. It was evident that the insights on cleaning polycrystalline gold disk electrodes with a benchmark electrode surface for DNA sensors, cannot be transferred to clean these miniature gold-sputtered microelectrodes. Therefore, a comparison between five different cleaning protocols was made to find the optimal one for gold-sputtered microelectrodes. Additionally, two principally different immobilization techniques for gold-sputtered microelectrode modification with thiolated ssDNA were compared i.e., immobilization through passive chemisorption and potential perturbation were compared in terms of thiol-specific attachment and thiol-unspecific adsorption through nitrogenous bases. The hybridization performance of these prepared electrodes was characterized by their sensitive complementary DNA capturing ability, detected by a standard alkaline phosphatase assay. Immobilization through passive chemisorption proved to be efficient in capturing the complementary target DNA with a detection limit of 0.14 nM and sensitivity of 9.38 A M−1 cm2. In general, this work presents a comprehensive understanding of cleaning, modification and performance of gold-sputtered microelectrodes with built-in gold reference and counter electrodes for both fundamental investigations and practical DNA sensing applications.
Keywords: A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.2
DOI: 10.1039/D0AN01387K
|
|
|
“Native mass spectrometry for the design and selection of protein bioreceptors for perfluorinated compounds”. Daems E, Moro G, Berghmans H, Moretto LM, Dewilde S, Angelini A, Sobott F, De Wael K, Analyst 146, 2065 (2021). http://doi.org/10.1039/D0AN02005B
Abstract: Biosensing platforms are answering the increasing demand for analytical tools for environmental monitoring of small molecules, such as per- and polyfluoroalkyl substances (PFAS). By transferring toxicological findings in bioreceptor design we can develop innovative pathways for biosensor design. Indeed, toxicological studies provide fundamental information about PFAS-biomolecule complexes that can help evaluate the applicability of the latter as bioreceptors. The toolbox of native mass spectrometry (MS) can support this evaluation, as shown by the two case studies reported in this work. The analysis of model proteins’ (i.e. albumin, haemoglobin, cytochrome c and neuroglobin) interactions with well-known PFAS, such as perfluorooctanoic acid (PFOA) and perfluorooctanesulfonic acid (PFOS), demonstrated the potential of this native MS screening approach. In the first case study, untreated albumin and delipidated albumin were compared in the presence and absence of PFOA confirming that the delipidation step increases albumin affinity for PFOA without affecting protein stability. In the second case study, the applicability of our methodology to identify potential bioreceptors for PFOS/PFOA was extended to other proteins. Structurally related haemoglobin and neuroglobin revealed a 1 : 1 complex, whereas no binding was observed for cytochrome c. These studies have value as a proof-of-concept for a general application of native MS to identify bioreceptors for toxic compounds.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 3.885
DOI: 10.1039/D0AN02005B
|
|
|
“Can plasma spectrochemistry assist in improving the accuracy of chemical analysis?”.Adams F, Adriaens A, Bogaerts A, Analytica chimica acta 456, 63 (2002). http://doi.org/10.1016/S0003-2670(02)00010-7
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 4.95
Times cited: 6
DOI: 10.1016/S0003-2670(02)00010-7
|
|
|
“Determination of gold at the ultratrace level in natural waters”. Cidu R, Fanfani L, Shaud P, Edmunds WM, Van 't dack L, Gijbels R, Analytica chimica acta 296, 295 (1994). http://doi.org/10.1016/0003-2670(94)80249-1
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 4.513
Times cited: 20
DOI: 10.1016/0003-2670(94)80249-1
|
|
|
“Determination of precious metals in ores and rocks by thermal neutron activation/\gamma-spectrometry after preconcentration by nickel sulphide fire assay and coprecipitation with tellurium”. Shazali I, Van 't dack L, Gijbels R, Analytica chimica acta 196, 49 (1987). http://doi.org/10.1016/S0003-2670(00)83069-X
Abstract: The six platinum group elements (Ru, Rh, Pd, Os, Ir and Pt) can be determined in geological samples down to the μg kg−1 level, by using nickel sulphide fire assay and neutron activation of the residue ramaining after dissolution of the nickel sulphide button in concentrated hydrochloric acid. Losses for the platinum group elements during this dissolution step are usually insignificant, except when the elements are present at ultra-trace levels. The can be recovered from the filtrate by coprecipitation with tellerium. The latter approach also permits determination of silver, which is significantly lost in the hydrochloric acid treatment (recovery <98% instead of typically ≈ 10%). The coprecipitation with tellurium considerably improves the results for gold (recovery ≈ 95% instead of typically 75%).
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 4.513
Times cited: 49
DOI: 10.1016/S0003-2670(00)83069-X
|
|
|
“Determination of silicon in natural and pollution aerosols by 14-MeV neutron activation analysis”. Gijbels R, Dams R, Analytica chimica acta 63, 369 (1973). http://doi.org/10.1016/S0003-2670(01)82362-X
Abstract: The determination of silicon via the 28Si(n,p)28 Al reaction by means of 14-MeV neutrons is applied to the analysis of pollution and natural aerosols. A Whatman 41 filter (40 cm2) on which airborne particulate material has been collected is compressed into a 3 × 12.7 mm pellet. Standards are prepared in the same way from clean filters spiked with a silicate solution. After a 50-s irradiation and a 75-s decay time, the sample is counted for 2 min with 5 × 5 NaI(Tl) well detector. The 1.779-MeV photopeak of 28Al is measured with a single channel sealer chain or with a multichannel analyser. The reproducibility, sensitivity and liability to interference from other elements were investigated for both counting systems. The homogeneity of the pellets and the filters was checked. The overall precision of one single-channel determination was estimated to be 3.5% after a 24-h high-volume sampling time. Samples collected in urban, industrial and remote areas with concentrations ranging from 0.05 to 15 μg Si m-3 air were analysed and the results are discussed.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)
Impact Factor: 4.513
Times cited: 16
DOI: 10.1016/S0003-2670(01)82362-X
|
|
|
“The determination of silicon in steel by 14-mev neutron activation analysis”. van Grieken R, Gijbels R, Speecke A, Hoste J, Analytica chimica acta 43, 199 (1968). http://doi.org/10.1016/S0003-2670(00)89208-9
Abstract: A fast (25 min) non-destructive determination of silicon in steel by 14-MeV neutron activation is described. The 1.78-MeV 28Al activity, induced by the reaction 28Si(n,p)28Al, is counted on a NaI(Tl) detector. An oxygen flux monitor is used to normalise to the same neutron flux. Two methods are described to correct for the 56Mn activity (2.58 h), induced into the iron matrix via 56Fe(n,p)56Mn. Nuclear interferences of phosphorus and aluminium have been examined. Special attention has been paid to stainless steels. A sensitivity of 0.02 to 0.05% of silicon is obtained. The precision is 2 to 3% for steels containing above 1% silicon, and 7% for 0.1% of silicon.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.513
Times cited: 19
DOI: 10.1016/S0003-2670(00)89208-9
|
|
|
“Internal standard activation analysis of silicon in steel”. van Grieken R, Gijbels R, Speecke A, Hoste J, Analytica chimica acta 43, 381 (1968). http://doi.org/10.1016/S0003-2670(00)89235-1
Abstract: Non-destructive 14-MeV neutron activation analysis for silicon in steel has been applied with 56Mn as internal standard.56Mn is formed from the iron matrix via the 56Fe(n,p)56Mn reaction. Several methods of internal standardisation via56Mn are discussed. The 0.84-MeV photopeak of 56Mn is recommended if steel samples of about the same composition are to be analysed. Chemically analysed steel samples are used as silicon standards. A precision of 0.7% was obtained for an analysis plus standardisation time of 13 min. Special attention was paid to interferences produced by concentration changes of impurity elements. Several possible sources of errors were investigated.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.513
Times cited: 14
DOI: 10.1016/S0003-2670(00)89235-1
|
|
|
“Laser microprobe Fourier transform mass spectrometer with external ion source for organic and inorganic microanalysis”. Struyf H, van Roy W, van Vaeck L, van Grieken R, Gijbels R, Caravatti P, Analytica chimica acta 283, 139 (1993). http://doi.org/10.1016/0003-2670(93)85216-7
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.513
Times cited: 17
DOI: 10.1016/0003-2670(93)85216-7
|
|
|
“Systematic errors in 14-MeV neutron activation analysis for oxygen : part 1 : neutron and γ-ray attenuation effects”. Vandecasteele C, van Grieken R, Gijbels R, Speecke A, Analytica chimica acta 64, 187 (1973). http://doi.org/10.1016/S0003-2670(01)82436-3
Abstract: A detailed account is given of neutron and γ-ray attenuation effects in 14-MeV neutron activation analysis of oxygen. Appropriate neutron cross-section values have been determined in two different ways and compared with literature values. It appears that the attenuation process is best described in terms of nonelastic scattering cross-sections. It is also shown that the narrow beam total γ-ray attenuation coefficients at 6 MeV, given in the literature are suitable for correction purposes if 16N γ-rays are counted with a window of 4.56.5 MeV. Attention was paid to the contribution of β-rays when the 16N activity is counted in this energy interval with a NaI(Tl) detector.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.513
Times cited: 11
DOI: 10.1016/S0003-2670(01)82436-3
|
|
|
“Systematic errors in 14-MeV neutron activation analysis for oxygen : part 2 : a general standardization method for the determination of oxygen”. Vandecasteele C, van Grieken R, Gijbels R, Speecke A, Analytica chimica acta 65, 1 (1973). http://doi.org/10.1016/S0003-2670(01)80158-6
Abstract: A general standardization method is described for the determination of oxygen in solid samples via the 16O(n,p)16N reaction. Two systems of flux monitoring are considered: the sample versus standard comparator method and BF3 monitoring. The average flux in sample and standard, fast neutron shielding, fast neutron scattering, absorption of fast neutrons, absorption of 16N γ-rays and counting efficiency of sample and standard are considered. The influence of the target diameter on the obtained correction factors has also been studied. Total achievable accuracy is believed to be about 1%.
Keywords: A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
Impact Factor: 4.513
Times cited: 12
DOI: 10.1016/S0003-2670(01)80158-6
|
|
|
“Evaluation of energy-dispersive x-ray-spectra with the aid of expert systems”. Janssens K, van Espen P, Analytica chimica acta 191, 169 (1986). http://doi.org/10.1016/S0003-2670(00)86306-0
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/S0003-2670(00)86306-0
|
|
|
“Implementation of an expert system for the qualitative interpretation of x-ray-fluorescence spectra”. Janssens K, van Espen P, Analytica chimica acta 184, 117 (1986). http://doi.org/10.1016/S0003-2670(00)86475-2
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
DOI: 10.1016/S0003-2670(00)86475-2
|
|
|
“Microanalytical characterization of surface decoration in Majolica pottery”. Padilla R, Schalm O, Janssens K, Arrazcaeta R, van Espen P, Analytica chimica acta 535, 201 (2005). http://doi.org/10.1016/J.ACA.2004.11.082
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Chemometrics (Mitac 3)
Impact Factor: 4.95
Times cited: 20
DOI: 10.1016/J.ACA.2004.11.082
|
|
|
“Surface microanalysis”. Adams F, Adriaens A, Berghmans P, Janssens K, Analytica chimica acta 283, 19 (1993). http://doi.org/10.1016/0003-2670(93)85207-Z
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0003-2670(93)85207-Z
|
|
|
“Synchrotron radiation-induced X-ray microanalysis”. Janssens K, Vincze L, Adams F, Jones KW, Analytica chimica acta 283, 98 (1993). http://doi.org/10.1016/0003-2670(93)85213-4
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/0003-2670(93)85213-4
|
|
|
“Analysis of rain water by differential-pulse stripping voltammetry in nitric acid medium”. Komy Z, Roekens E, Van Grieken R, Analytica chimica acta 204, 179 (1988). http://doi.org/10.1016/S0003-2670(00)86357-6
Abstract: Differential-pulse anodic stripping voltammetry is applied to determine cadmium, lead and copper in rain water acidified with nitric acid to pH 1.5, and zinc after partial neutralization to pH 4.5. Subsequently, cobalt and nickel are measured in the adsorptive mode after formation of their dimethylglyoximates. The effects of pH on the stripping peaks for Zn, Cd, Pb and Cu and of chloride on the stripping peak of copper are reported. Good agreement is found with d.p.s.v. determinations in hydrochloric acid medium and with a.a.s. measurements in most cases. Excellent accuracy is demonstrated; the average relative standard deviation per measurement appears to be between 12 and 22% for the overall analytical procedure for concentrations of 0.1550 μgl−1 of the various metals in the samples.
Keywords: A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
DOI: 10.1016/S0003-2670(00)86357-6
|
|
|
“Application of chemometric methods for classification of atmospheric particles based on thin-window electron probe microanalysis data”. Osán J, de Hoog J, Worobiec A, Ro C-U, Oh K-Y, Szalóki I, Van Grieken R, Analytica chimica acta 446, 211 (2001)
Keywords: A1 Journal article; Laboratory Experimental Medicine and Pediatrics (LEMP); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)
|
|