toggle visibility
Search within Results:
Display Options:

Select All    Deselect All
 |   | 
Details
   print
  Records Links
Author Alvarez-Martin, A.; Trashin, S.; Cuykx, M.; Covaci, A.; De Wael, K.; Janssens, K. pdf  url
doi  openurl
  Title Photodegradation mechanisms and kinetics of Eosin-Y in oxic and anoxic conditions Type A1 Journal article
  Year 2017 Publication Dyes and pigments Abbreviated Journal Dyes Pigments  
  Volume 145 Issue Pages (down) 376-384  
  Keywords A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Toxicological Centre  
  Abstract Lakes based on Eosin-Y are extensively used by 19th century artists. Unfortunately, the identification of these pigments in paintings is a difficult task because Eosin-Y degrades very fast under the influence of light. The characterization of the (photo)degradation products of Eosin-Y can be very useful for the identification of these pigments in historic works of art and related cultural heritage artifacts. Furthermore, knowledge on how different factors influence the discoloration process (e.g. different types of irradiation sources and presence/absence of oxygen) is a valuable tool for preventive conservation. To this aim we performed a study on the photodegradation of Eosin-Y in solution under different illumination and in both oxic and anoxic conditions. The photodegradation of Eosin-Y was monitored by UV-VIS spectrophotometry, LC-QTOFMS and electrochemistry techniques. Results indicated higher degradation rates, by a factor of 20 or higher, under illumination with wavelengths near to the main absorbance band of the red pigment. Two different degradation pathways are observed under the conditions studied. LC-QTOFMS and electrochemistry suggested that in the presence of oxygen the degradation mechanism is an oxidative process where the breakdown of the structure causes the total discoloration. Meanwhile under anoxic conditions, a debromination process takes place while the chromophore, and consequently the color of the molecule in solution, remains essentially intact.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 000405972900046 Publication Date 2017-06-16  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0143-7208 ISBN Additional Links UA library record; WoS full record; WoS citing articles  
  Impact Factor 3.473 Times cited 18 Open Access  
  Notes ; ; Approved Most recent IF: 3.473  
  Call Number UA @ admin @ c:irua:144385 Serial 5770  
Permanent link to this record
 

 
Author Kontozova-Deutsch, V.; Deutsch, F.; Bencs, L.; Krata, A.; Van Grieken, R.; De Wael, K. pdf  doi
openurl 
  Title Optimization of the ion chromatographic quantification of airborne fluoride, acetate and formate in the Metropolitan Museum of Art, New York Type A1 Journal article
  Year 2011 Publication Talanta : the international journal of pure and applied analytical chemistry Abbreviated Journal Talanta  
  Volume 86 Issue Pages (down) 372-376  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract Ion chromatographic (IC) methods have been compared in order to achieve an optimal separation of fluoride, acetate and formate under various elution conditions on two formerly introduced analytical columns (i and ii) and a novel one (iii): (i) an IonPac AS14 (250 mm × 4 mm I.D.), (ii) Allsep A-2 (150 mm × 4.6 mm I.D.), and (iii) an IC SI-50 4E (250 mm (length) × 4 mm (internal diameter – I.D.)). The IC conditions for the separation of the anions concerned were optimized on the IC SI-50 4E column. A near baseline separation of these anions was attained on the IonPac AS14, whereas the peaks of fluoride and acetate could not be resolved on the Allsep A-2. A baseline separation for the three anions was achieved on the IC SI-50 4E column, when applying an eluent mixture of 3.2 mmol/L Na2CO3 and 1.0 mmol/L NaHCO3 with a flow rate of 1.0 mL/min. The highest precision of 1.7, 3.0 and 2.8% and the best limits of detection (LODs) of 0.014, 0.22 and 0.17 mg/L for fluoride, acetate and formate, respectively, were obtained with the IC SI-50 4E column. Hence, this column was applied for the determination of the acetic and formic acid contents of air samples taken by means of passive gaseous sampling at the Metropolitan Museum of Art in New York, USA. Atmospheric concentrations of acetic and formic acid up to 1050 and 450 μg/m3, respectively, were found in non-aerated showcases of the museum. In galleries and outdoors, rather low levels of acetic and formic acid were detected with average concentrations of 50 and 10 μg/m3, respectively. The LOD data of acetate and formate on the IC SI-50 4E column correspond to around 0.5 μg/m3 for both acetic and formic acid in air samples.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 000298126300048 Publication Date 2011-09-24  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0039-9140; 1873-3573 ISBN Additional Links UA library record; WoS full record; WoS citing articles  
  Impact Factor 4.162 Times cited 19 Open Access  
  Notes ; The authors gratefully acknowledge the support of Marco Leona and the staff of the Metropolitan Museum of Art in New York during the sampling campaigns. The technical assistance and advice by Dr. Takashi Kotsuka and Shodex Benelux are acknowledged as well. ; Approved Most recent IF: 4.162; 2011 IF: 3.794  
  Call Number UA @ admin @ c:irua:92066 Serial 5762  
Permanent link to this record
 

 
Author Florea, A.; Cowen, T.; Piletsky, S.; De Wael, K. pdf  url
doi  openurl
  Title Polymer platforms for selective detection of cocaine in street samples adulterated with levamisole Type A1 Journal article
  Year 2018 Publication Talanta : the international journal of pure and applied analytical chemistry Abbreviated Journal Talanta  
  Volume 186 Issue 186 Pages (down) 362-367  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract Accurate drug detection is of utmost importance for fighting against drug abuse. With a high number of cutting agents and adulterants being added to cut or mask drugs in street powders the number of false results is increasing. We demonstrate for the first time the usefulness of employing polymers readily synthesized by electrodeposition to selectively detect cocaine in the presence of the commonly used adulterant levamisole. The polymers were selected by computational modelling to exhibit high binding affinity towards cocaine and deposited directly on the surface of graphene-modified electrodes via electropolymerization. The resulting platforms allowed a distinct electrochemical signal for cocaine, which is otherwise suppressed by levamisole. Square wave voltammetry was used to quantify cocaine alone and in the presence of levamisole. The usefulness of the platforms was demonstrated in the screening of real street samples.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 000435048800049 Publication Date 2018-04-25  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0039-9140; 1873-3573 ISBN Additional Links UA library record; WoS full record; WoS citing articles  
  Impact Factor 4.162 Times cited 9 Open Access  
  Notes ; This project has received funding from the European Union's Horizon 2020 Research and Innovation Programme under the Marie Sklodowska-Curie Grant Agreement no. 753223 Narcoreader. This work was also supported by IOF-SBO (UAntwerp). The authors thank Gert Nuyts for the help with SEM analyses. ; Approved Most recent IF: 4.162  
  Call Number UA @ admin @ c:irua:151250 Serial 5777  
Permanent link to this record
 

 
Author Anaf, W.; Bencs, L.; Van Grieken, R.; Janssens, K.; De Wael, K. pdf  url
doi  openurl
  Title Indoor particulate matter in four Belgian heritage sites : case studies on the deposition of dark-colored and hygroscopic particles Type A1 Journal article
  Year 2015 Publication The science of the total environment Abbreviated Journal Sci Total Environ  
  Volume 506 Issue Pages (down) 361-368  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract Atmospheric total suspended particulate (TSP) was passively sampled by means of deployed horizontal and vertical filters in various rooms of four Belgian cultural heritage buildings, installed with various heating/ventilation systems. Soiling/blackening and deposition of inorganic, water-soluble aerosol components were considered. The extent of soiling was determined by means of two independent methods: (1) in terms of the covering rate of the samplers by optical reflection microscopy and (2) the reduction in lightness of the samplers using the CIE L*a*b* color space by spectrophotometry. A fairly good correlation was found between both methods. The inorganic composition of the deposited water-soluble TSP was quantified by means of ion chromatography. Compared to controlled environments, uncontrolled environments showed increased water-soluble aerosol content of the total deposited mass. Higher chloride deposition was observed on horizontal surfaces, compared to vertical surfaces.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 000347576800039 Publication Date 2014-11-24  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0048-9697 ISBN Additional Links UA library record; WoS full record; WoS citing articles  
  Impact Factor 4.9 Times cited 12 Open Access  
  Notes ; ; Approved Most recent IF: 4.9; 2015 IF: 4.099  
  Call Number UA @ admin @ c:irua:120640 Serial 5662  
Permanent link to this record
 

 
Author Krupińska, B.; Van Grieken, R.; De Wael, K. pdf  doi
openurl 
  Title Air quality monitoring in a museum for preventive conservation : results of a three-year study in the Plantin-Moretus Museum in Antwerp, Belgium Type A1 Journal article
  Year 2013 Publication Microchemical journal Abbreviated Journal Microchem J  
  Volume 110 Issue Pages (down) 350-360  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract Through different research projects on air quality in museums, researcher and conservators try identifying various risks of air pollution on materials. The conclusions may be later translated into specific actions for a maximum preservation of the museum collections, a process known as preventive conservation. Air pollution is a particular problem in historical buildings such as museums, because they were not originally built to exhibit and protect art objects in a sustainable way. This article reports on the data and results that were obtained during 10 sampling campaigns, in the period between November 2008 and February 2012 in a museum in Antwerp (Belgium), i.e. Plantin-Moretus Museum/Print Room. Different pollutants were measured inside and outside the museum such as inorganic gases, particulate matter and black carbon. The report specifically addresses environmental factors that may be responsible for damage to the collections present in museums. Thanks to the knowledge about the current situation in the museum, accurate solutions regarding preventive conservation, in general, are suggested.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 000326851200051 Publication Date 2013-05-21  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0026-265x; 0026-265x ISBN Additional Links UA library record; WoS full record; WoS citing articles  
  Impact Factor 3.034 Times cited 46 Open Access  
  Notes ; The presented work was realised in the frame of the project Preventive conservation/preservation in the museum Plantin-Moretus/Prentenkabinet, Antwerp, financed by the Flemish Government. Special thanks are due to Mrs Hanne Moris and Mrs Elke van Herck and all the staff of the Museum Plantin-Moretus/Print Room in Antwerp for their sincere interest in this work and their eager assistance during all the sampling campaigns. VMM and Dr. Edward Roekens is acknowledged for sharing the black carbon measurements. Barbara Krupinska is supported as PhD student by the Flemish Fund for Scientific Research (FWO, Belgium). ; Approved Most recent IF: 3.034; 2013 IF: 3.583  
  Call Number UA @ admin @ c:irua:108402 Serial 5460  
Permanent link to this record
 

 
Author Rahemi, V.; Trashin, S.; Hafideddine, Z.; Meynen, V.; Van Doorslaer, S.; De Wael, K. pdf  url
doi  openurl
  Title Enzymatic sensor for phenols based on titanium dioxide generating surface confined ROS after treatment with H2O2 Type A1 Journal article
  Year 2019 Publication Sensors and actuators : B : chemical Abbreviated Journal Sensor Actuat B-Chem  
  Volume 283 Issue 283 Pages (down) 343-348  
  Keywords A1 Journal article; Laboratory of adsorption and catalysis (LADCA); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract Titanium dioxide (TiO2) is a popular material as host matrix for enzymes. We now evidence that TiO2 can accumulate and retain reactive oxygen species after treatment by hydrogen peroxide (H2O2) and support redox cycling of a phenolic analyte between horseradish peroxidase (HRP) and an electrode. The proposed detection scheme is identical to that of second generation biosensors, but the measuring solution requires no dissolved H2O2. This significantly simplifies the analysis and overcomes issues related to H2O2 being present (or generated) in the solution. The modified electrodes showed rapid stabilization of the baseline, a low noise level, fast realization of a steady-state current response, and, in addition, improved sensitivity and limit of detection compared to the conventional approach, i.e. in the presence of H2O2 in the measuring solution. Hydroquinone, 4-aminophenol, and other phenolic compounds were successfully detected at sub-μM concentrations. Particularly, a linear response in the concentration range between 0.025 and 2 μM and LOD of 24 nM was demonstrated for 4-aminophenol. The proposed sensor design goes beyond the traditional concept with three sensors generations offering a new possibility for the development of enzymatic sensors based on peroxidases and the formation of ROS on titania after treatment with H2O2.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 000455854000043 Publication Date 2018-12-10  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0925-4005 ISBN Additional Links UA library record; WoS full record; WoS citing articles  
  Impact Factor 5.401 Times cited 1 Open Access  
  Notes ; The authors thank the University of Antwerp for GOA funding and the Scientific Research-Flanders (FWO) (grant 12T4219N). V. Rahemi is financially supported through a postdoctoral fellowship of the Research Foundation-Flanders (FWO). ; Approved Most recent IF: 5.401  
  Call Number UA @ admin @ c:irua:155665 Serial 5605  
Permanent link to this record
 

 
Author Kuckova, S.; Hamidi-Asl, E.; Matulkova, I.; Hynek, R.; De Wael, K.; Sanyova, J.; Janssens, K. openurl 
  Title Technoques and applications of Surface-Enhanced Raman Scattering Spectroscopy (SERSS) focused on cultural heritage Type A1 Journal article
  Year 2018 Publication Chemické listy Abbreviated Journal Chem Listy  
  Volume 112 Issue 5 Pages (down) 312-316  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract The review is devoted to a modern method of vibrational spectroscopy – surface enhanced Raman spectroscopy Its principle and some of its special variants (imunnoSERS and TERS (Tip-Enhanced Raman Spectroscopy)) are described m a simpinified manner Wide application possibilities are demonstrated on selected examples from its application m culturinl heritage.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos Publication Date  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0009-2770; 1213-7103 ISBN Additional Links UA library record; WoS full record  
  Impact Factor 0.387 Times cited Open Access  
  Notes ; ; Approved Most recent IF: 0.387  
  Call Number UA @ admin @ c:irua:151616 Serial 5869  
Permanent link to this record
 

 
Author Khan, S.U.; Trashin, S.A.; Korostei, Y.S.; Dubinina, T.V.; Tomilova, L.G.; Verbruggen, S.W.; De Wael, K. pdf  doi
openurl 
  Title Photoelectrochemistry for measuring the photocatalytic activity of soluble photosensitizers Type A1 Journal article
  Year 2020 Publication ChemPhotoChem Abbreviated Journal  
  Volume 4 Issue 4 Pages (down) 300-306  
  Keywords A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Sustainable Energy, Air and Water Technology (DuEL)  
  Abstract We introduce a rapid method to test the photocatalytic activity of singlet‐oxygen‐producing photosensitizers using a batch cell, a LED laser and a conventional potentiostat. The strategy is based on coupling of photo‐oxidation of hydroquinone and simultaneous electrochemical reduction of its oxidized form at a carbon electrode in an organic solvent (methanol). This scheme gives an immediate response and avoids complications related to long‐term experiments such as oxidative photo‐degradation of photosensitizers and singlet oxygen traps by reactive oxygen species (ROS). Among the tested compounds, a fluoro‐substituted subphthalocyanine showed the highest photocurrent and singlet oxygen quantum yield (ΦΔ) in comparison to phenoxy‐ and tert‐butyl‐substituted analogues, whereas the lowest photocurrents and yields were observed for aggregated and dimeric phthalocyanine complexes. The method is useful for fast screening of the photosensitizing activity and represents the first example of one‐pot coupling of electrochemical and photocatalytic reactions in organic media.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 000520100400001 Publication Date 2020-01-25  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 2367-0932 ISBN Additional Links UA library record; WoS full record; WoS citing articles  
  Impact Factor 3.7 Times cited 1 Open Access  
  Notes ; We gratefully acknowledge the financial support by ERA.Net RUS Plus Plasmon Electrolight project (No. 18-53-76006 ERA) and RSF 17-13-01197. ; Approved Most recent IF: 3.7; 2020 IF: NA  
  Call Number UA @ admin @ c:irua:165912 Serial 5771  
Permanent link to this record
 

 
Author Thirumalraj, alamurugan; Palanisamy, S.; Chen, S.-M.; De Wael, K. pdf  url
doi  openurl
  Title A graphene/gelatin composite material for the entrapment of hemoglobin for bioelectrochemical sensing applications Type A1 Journal article
  Year 2016 Publication Journal of the electrochemical society Abbreviated Journal J Electrochem Soc  
  Volume 163 Issue 7 Pages (down) 265-271  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract In the present work, a novel graphene (GN) and gelatin (GTN) composite was prepared and used as an immobilization matrix for hemoglobin (Hb). Compared with Hb immobilized on a bare, GN or GTN modified glassy carbon electrode (GCE), a stable and pair of well-defined quasi redox couple was observed at an Hb modified GN/GTN composite GCE at a formal potential of −0.306 V versus Ag|AgCl. The direct electrochemical behavior of Hb was greatly enhanced by the presence of both GTN and GN. A heterogeneous electron transfer rate constant (Ks) was calculated as 3.82 s−1 for Hb immobilized at GN/GTN modified GCE, which indicates the fast direct electron transfer of Hb toward the electrode surface. The biosensor shows a stable and wide linear response for H2O2 in the linear response range from 0.1 μM to 786.6 μM with an analytical sensitivity and limit of detection of 0.48 μAμM−1 cm−2 and 0.04 μM, respectively. The fabricated biosensor holds its high selectivity in the presence of potentially active interfering species and metal ions. The biosensor shows its satisfactory practical ability in the commercial contact lens solution and human serum samples.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 000377412900047 Publication Date 2016-04-08  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0013-4651 ISBN Additional Links UA library record; WoS full record; WoS citing articles  
  Impact Factor 3.259 Times cited 9 Open Access  
  Notes ; This project was supported by the Ministry of Science and Technology (project no. NSC1012113M027001MY3), Taiwan (Republic of China). The authors express their sincere thanks to Prof. Bih-Show Lou, Chemistry Division, Center for General Education, Chang Gung University, Tao-Yuan, Taiwan for providing the human serum samples. ; Approved Most recent IF: 3.259  
  Call Number UA @ admin @ c:irua:132627 Serial 5635  
Permanent link to this record
 

 
Author Ayalew, E.; Gebre, Y.; De Wael, K. url  doi
openurl 
  Title A survey of occupational exposure to inhalable wood dust among workers in small- and medium-scale wood-processing enterprises in Ethiopia Type A1 Journal article
  Year 2015 Publication The annals of occupational hygiene Abbreviated Journal Ann Occup Hyg  
  Volume 59 Issue 2 Pages (down) 253-257  
  Keywords A1 Journal article; Pharmacology. Therapy; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract A study of wood dust exposure in 20 small- and medium-scale wood-processing enterprises was performed in Ethiopia. Sampling was conducted daily from January to June, 2013 and a total of 360 samples from 113 workers were collected with Institute of Occupational Medicine (IOM) personal samplers. Eight-hour time-weighted average exposure to wood dust ranged from 0.24 to 23.3mg m−3 with a geometric mean (GM) of 6.82mg m−3 and a geometric standard deviation of 1.82. Although Ethiopia did not have any defined standard of Occupational Exposure Limit for wood dust exposure, 71% of the measurements exceeded the limit of 5mg m−3 set by the European Union (EU). Higher than the EU exposure limit was measured while workers perform sanding and sawing activities with a GM of 9.72 and 7.60mg m−3, respectively. In conclusion, wood workers in the small- and medium-scale enterprises are at a higher risk of developing different respiratory health problems with continuous exposure trends.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 000352158700011 Publication Date 2014-10-28  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0003-4878 ISBN Additional Links UA library record; WoS full record; WoS citing articles  
  Impact Factor 1.71 Times cited 4 Open Access  
  Notes ; Eyasu Ayalew thanks the Addis Ababa University (Center for Environmental Sciences) for the personal grant for independent study. ; Approved Most recent IF: 1.71; 2015 IF: 2.101  
  Call Number UA @ admin @ c:irua:119739 Serial 5857  
Permanent link to this record
 

 
Author Morales-Yánez, F.; Trashin, S.; Sariego, I.; Roucher, C.; Paredis, L.; Chico, M.; De Wael, K.; Muyldermans, S.; Cooper, P.; Polman, K. url  doi
openurl 
  Title Electrochemical detection of Toxocara canis excretory-secretory antigens in children from rural communities in Esmeraldas Province, Ecuador : association between active infection and high eosinophilia Type A1 Journal article
  Year 2020 Publication Parasites & Vectors Abbreviated Journal Parasite Vector  
  Volume 13 Issue 1 Pages (down) 245-247  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract Background The diagnosis of active Toxocara canis infections in humans is challenging. Larval stages of T. canis do not replicate in human tissues and disease may result from infection with a single T. canis larva. Recently, we developed a nanobody-based electrochemical magnetosensor assay with superior sensitivity to detect T. canis excretory-secretory (TES) antigens. Here, we evaluate the performance of the assay in children from an Ecuadorian birth cohort that followed children to five years of age. Methods Samples were selected based on the presence of peripheral blood eosinophilia and relative eosinophil counts. The samples were analyzed by the nanobody-based electrochemical magnetosensor assay, which utilizes a bivalent biotinylated nanobody as capturing agent on the surface of streptavidin pre-coated paramagnetic beads. Detection was performed by a different nanobody chemically labelled with horseradish peroxidase. Results Of 87 samples tested, 33 (38%) scored positive for TES antigen recognition by the electrochemical magnetosensor assay. The average concentration of TES antigen in serum was 2.1 ng/ml (SD = 1.1). The positive result in the electrochemical assay was associated with eosinophilia > 19% (P = 0.001). Parasitological data were available for 57 samples. There was no significant association between positivity by the electrochemical assay and the presence of other soil-transmitted helminth infections. Conclusions Our nanobody-based electrochemical assay provides highly sensitive quantification of TES antigens in serum and has potential as a valuable tool for the diagnosis of active human toxocariasis.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 000535618800003 Publication Date 2020-05-12  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1756-3305 ISBN Additional Links UA library record; WoS full record; WoS citing articles  
  Impact Factor 3.2 Times cited Open Access  
  Notes ; This project was funded by the Fonds Wetenschappelijk Onderzoek-Vlaanderen (FWO-Flanders), project No. G.0189.13N. The ECUAVIDA cohort was funded by the Wellcome Trust (grant 072405/Z/03/Z and 088862/Z/09/Z). ; Approved Most recent IF: 3.2; 2020 IF: 3.08  
  Call Number UA @ admin @ c:irua:168966 Serial 6501  
Permanent link to this record
 

 
Author Pauwels, D.; Geboes, B.; Hereijgers, J.; Choukroun, D.; De Wael, K.; Breugelmans, T. pdf  url
doi  openurl
  Title The application of an electrochemical microflow reactor for the electrosynthetic aldol reaction of acetone to diacetone alcohol Type A1 Journal article
  Year 2017 Publication Chemical engineering research and design Abbreviated Journal Chem Eng Res Des  
  Volume 128 Issue Pages (down) 205-213  
  Keywords A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Laboratory Experimental Medicine and Pediatrics (LEMP); Applied Electrochemistry & Catalysis (ELCAT)  
  Abstract The design and application of an electrochemical micro-flow reactor for the aldol reaction of acetone to diacetone alcohol (DAA) is reported. The modular reactor could be readily disassembled and reassembled to change the electrodes, incorporate a membrane and remove possible obstructions. The productivity and efficiency was quantified. Using a platinum deposit as electrocatalyst or an inert glassy carbon electrode as working electrode, the maximum obtainable equilibrium concentration of ±15 m% was reached after a single pass up to a flow rate of 8 ml min−1, yielding 0.57 g min−1 DAA (3.46 mmol cm−3 min−1) at an efficiency of 0.33 g C−1 on platinum and 0.50 g min−1 (3.04 mmol cm−3 min−1) at 1.20 g C−1 on glassy carbon. Note that no optimisation studies have been made in the present paper.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 000424736500018 Publication Date 2017-10-20  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0263-8762 ISBN Additional Links UA library record; WoS full record; WoS citing articles  
  Impact Factor 2.538 Times cited 2 Open Access  
  Notes ; The authors would like to thank Bert De Mot for assisting with the measurements. Jonas Hereijgers greatly acknowledges the Research Foundation – Flanders (FWO) for support through a Post-Doctoral grant (12Q8817N). ; Approved Most recent IF: 2.538  
  Call Number UA @ admin @ c:irua:146943 Serial 5871  
Permanent link to this record
 

 
Author Rather, J.A.; Pilehvar, S.; De Wael, K. doi  openurl
  Title A biosensor fabricated by incorporation of a redox mediator into a carbon nanotube/nafion composite for tyrosinase immobilization : detection of matairesinol, an endocrine disruptor Type A1 Journal article
  Year 2013 Publication The analyst Abbreviated Journal Analyst  
  Volume 238 Issue Pages (down) 204-210  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract An electrochemical matairesinol biosensor was fabricated by immobilizing tyrosinase on a poly(thionine)/nafion/multi-walled carbon nanotube composite film. A polymeric film of the redox dye thionine enables the stable immobilization of tyrosinase while acting as a mediator for the enzymatic process has been incorporated into the carbon nanotube/nafion composite film. The immobilization method is based on crosslinking of the tyrosinase layer with an electropolymerized film of poly(thionine). The good homogenization of the electron conductor CNTs in the integrated films provides the possibility of a three-dimensional electron conductive network. The biosensor was characterized by electrochemical impedance spectroscopy and electrochemical characterization. The composite electrode exhibits catalytic activity, high sensitivity, stability and is applicable over a wide range of concentrations from 180 nM to 4.33 μM with a detection limit (LOD) of 37 nM. The obtained results suggest that the developed sensor can be successfully used for the determination of phenolic endocrine disruptors over a concentration range covering their environmental levels.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 000311823200025 Publication Date 2012-10-26  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0003-2654 ISBN Additional Links UA library record; WoS full record; WoS citing articles  
  Impact Factor 3.885 Times cited 23 Open Access  
  Notes ; The authors are highly thankful for the mobility grant (Non-Europe Postdoc Fellowship) for one of the authors (Jahangir Ahmad Rather) supported by the Belgian Federal Science Policy (Belspo) co-funded by the Marie Curie Actions from the European Commission. ; Approved Most recent IF: 3.885; 2013 IF: 3.906  
  Call Number UA @ admin @ c:irua:101648 Serial 5490  
Permanent link to this record
 

 
Author Hellar-Kihampa, H.; De Wael, K.; Lugwisha, E.; Govindan, M.; Covaci, A.; Van Grieken, R. pdf  doi
openurl 
  Title Spatial monitoring of organohalogen compounds in surface water and sediments of a rural-urban river basin in Tanzania Type A1 Journal article
  Year 2013 Publication The science of the total environment Abbreviated Journal Sci Total Environ  
  Volume 447 Issue Pages (down) 186-197  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Toxicological Centre  
  Abstract The presence of persistent organic pollutants in Tanzanian environment is not well monitored despite the existing pollution potential from a number of sources. In this study, we investigated for the first time, the concentration profiles of different organohalogen compounds such as organochlorine pesticide residues (OCPs), polychlorinated biphenyls (PCBs) and polybrominated diphenyl ethers (PBDEs) in environmental samples (water and sediments) from the Pangani river basin (PRB). The PRB is one of the largest drainage basins in Tanzania, with its watershed exposed to multiple input sources of trace organic contaminants. Surface water and sediments were sampled from 12 representative stations of diverse characteristics and land-use practices, in three distinct seasons, and extracted by liquidliquid and Soxhlet extraction methods, respectively. Water samples were analyzed by GC-ECD for OCPs only, while sediment samples were analyzed for OCPs, PCBs and PBDEs by GC/MS. Seven compounds, dominated by HCH isomers (5104460 pg/L) and DDT analogs (1601460 pg/L),were detected in the water samples. These concentrations are far below the WHO guidelines for drinking water quality. A total of 42 compounds (8 OCPs, 28 PCB congeners and 6 PBDE congeners) were detected in the sediment samples. Their respective total concentration ranges were 24510,230; 35711,000 and 382175 pg/g dry weight. The spatial distribution patterns and Hierarchical Cluster Analysis reflected the impact of historical agricultural usage in sugarcane plantations (OCPs), and urbanization (PCBs and PBDEs). Risk assessment using sediment quality guidelines indicated no ecotoxicological risks. The results we have found provide preliminary data on levels of the organic contaminants in Pangani river basin as a new insight on the environmental quality of the area.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 000317538100022 Publication Date 2013-02-05  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0048-9697 ISBN Additional Links UA library record; WoS full record; WoS citing articles  
  Impact Factor 4.9 Times cited 42 Open Access  
  Notes ; This research project was funded by the International Foundation for Science (IFS, Project Number W/4945-1). The authors wish to acknowledge the contribution of the Pangani Basin Water Office (PBWO) in Moshi, Tanzania; especially Ms. Arafa Maggidi in provision of valuable information and assistance with the sampling campaigns, and Salim Lyimo in mapping of the study area. The contributions of Mr. Peter Machibya of the Department of Geology, University of Dar es Salaam, Tanzania in sediment characterization; and Mr. Emmanuel Gwae, of the Government Chemists Laboratory Agency (GCLA) Dar es Salaam, Tanzania, for instrumental analysis of the water samples, are highly appreciated. Harieth Hellar-Kihampa acknowledges financial support from the Belgian Technical Agency (BTC). Govindan Malarvannan and Adrian Covaci acknowledge financial support from the University of Antwerp. ; Approved Most recent IF: 4.9; 2013 IF: 3.163  
  Call Number UA @ admin @ c:irua:105260 Serial 5836  
Permanent link to this record
 

 
Author Marchetti, A.; Beltran, V.; Storme, P.; Nuyts, G.; Van Der Meeren, L.; Skirtach, A.; Otten, E.; Debulpaep, M.; Watteeuw, L.; De Wael, K. pdf  doi
openurl 
  Title All that glitters is not gold : unraveling the material secrets behind the preservation of historical brass Type A1 Journal article
  Year 2023 Publication Journal of cultural heritage Abbreviated Journal  
  Volume 63 Issue Pages (down) 179-186  
  Keywords A1 Journal article; Engineering sciences. Technology; Art; History; Antwerp Cultural Heritage Sciences (ARCHES); Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)  
  Abstract Brass is a relatively stable alloy but it tends to tarnish over time due to the interaction with the atmosphere. Thus, it is rare to observe centuries-old brass objects untouched by the passing of time. For this reason, the pristine appearance of hundreds of brass sequins in the Enclosed Gardens of Mechelen (reliquary altarpieces produced between 1530 and 1550) is remarkable. In this study, the chemical and metallographic characterization of such unexpectedly well-preserved objects is presented. The results revealed the reason for their stability to be a combination of high-quality materials (i.e. medium Zn content, low impurities) and optimal surface properties (i.e. high homogeneity, low roughness), indicating the high level of expertise of the craftsmen who produced them. Novel fundamental insights on the historical manufacturing method of metallic sequins were also obtained.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 001058894000001 Publication Date 2023-08-14  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1296-2074 ISBN Additional Links UA library record; WoS full record  
  Impact Factor 3.1 Times cited Open Access Not_Open_Access: Available from 15.08.2024  
  Notes Approved Most recent IF: 3.1; 2023 IF: 1.838  
  Call Number UA @ admin @ c:irua:198113 Serial 8830  
Permanent link to this record
 

 
Author Wuyts, K.; Hofman, J.; van Wittenberghe, S.; Nuyts, G.; De Wael, K.; Samson, R. pdf  url
doi  openurl
  Title A new opportunity for biomagnetic monitoring of particulate pollution in an urban environment using tree branches Type A1 Journal article
  Year 2018 Publication Atmospheric environment : an international journal Abbreviated Journal Atmos Environ  
  Volume 190 Issue 190 Pages (down) 177-187  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract Environmental magnetism, and the magnetic leaf signal in particular, is amply investigated and applied as proxy for atmospheric particulate matter pollution. In this study, we investigated the magnetic signal of annual segments of tree branches, and the composition of particles deposited hereon. Branches are, contrary to leaves of deciduous trees, available during leaf-off seasons and exposed to air pollution year-round. We examined the intra- and inter-tree variation in saturation isothermal remanent magnetization (SIRM) of branch internodes of London plane (Platanus x aeerifolia Willd.) trees in an urban environment. The branch SIRM, normalized by surface area, ranged from 18 to 650 x 10(-6) angstrom; the median amounted to 106 x 10(-6) angstrom. Most of the branch magnetic signal was attributed to the epidermis or bark, and the presence of metal-containing particles on the branch surfaces was confirmed by SEM-EDX. The location of the trees and the height, the depth in the crown and the age of the branches significantly influenced the branch SIRM. The median branch SIRM was up to 135% higher near a busy ring road than in quiet environments (city park and quiet street canyon), and was linked to the presence of Fe-rich particles with co-occurrence of trace metals such as Cr, Cu, Zn and Mn on the branch surface. Within the tree crowns, the branch SIRM generally decreased with increasing height, and was 22% higher in the interior than at the periphery of the crowns. Within the branches, the SIRM increased with each year of exposure, but did not relate to year-to-year variation in particle concentrations due to branch surface changes (epidermis shedding). Our results provide indications that branches can be a valuable alternative for biomagnetic monitoring of particulate pollution, but intra-tree variability in branch SIRM can be substantial due to the branch's location in the tree and branch age.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 000444659400017 Publication Date 2018-07-11  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1352-2310 ISBN Additional Links UA library record; WoS full record; WoS citing articles  
  Impact Factor 3.629 Times cited 3 Open Access  
  Notes ; We would like to thank the city council services of the city of Antwerp for their logistical support. We are grateful to Ana Castanheiro and Leen Van Ham for laboratory and SEM assistance. JH is supported as postdoctoral fellow of the Research Foundation Flanders (FWO; 12I4816N) and SVW is supported by a Marie Sklodowska-Curie Individual Fellowship under the grant agreement no 701815 FLUOPHOT. ; Approved Most recent IF: 3.629  
  Call Number UA @ admin @ c:irua:153607 Serial 5454  
Permanent link to this record
 

 
Author Pilehvar, S.; De Wael, K. isbn  openurl
  Title Recent advances in electrochemical biosensors based on fullerene-C60 nano-structured platforms Type H1 Book chapter
  Year 2017 Publication Abbreviated Journal  
  Volume Issue Pages (down) 173-196  
  Keywords H1 Book chapter; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos Publication Date  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN 978-1-119-24390-8 Additional Links UA library record  
  Impact Factor Times cited Open Access  
  Notes Approved Most recent IF: NA  
  Call Number UA @ admin @ c:irua:146374 Serial 5804  
Permanent link to this record
 

 
Author Qurashi, A.; Rather, J.A.; Yamazaki, T.; Sohail, M.; De Wael, K.; Merzougui, B.; Hakeem, A.S. pdf  url
doi  openurl
  Title Swift electrochemical detection of paraben an endocrine disruptor by In2O3 nanobricks Type A1 Journal article
  Year 2015 Publication Sensors and actuators : B : chemical Abbreviated Journal Sensor Actuat B-Chem  
  Volume 221 Issue Pages (down) 167-171  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract Novel indium oxide (In2O3) nanobricks have been prepared by template-less and surfactant-free hydrothermal synthesis method and were characterized by X-ray diffraction (XRD), Raman spectroscopy, photoluminescence (PL) spectroscopy and field emission scanning electronic microscopy (FESEM). The synthesized In2O3 nanobricks were successfully immobilized on the surface of glassy carbon electrode for the detection of Parabens (butylparaben). Owing to the unique structure and intriguing properties of these In2O3 nanobricks, the nanostructured thin-film electrode has shown an obvious electrocatalytic activity for the detection of butylparaben (BP). The detection limit (LOD) was estimated as 3 s/m and the sensitivity (LOQ) was calculated as 10 s/m and were found to be 0.08 μM and 0.26 μA μM−1 cm−2 respectively. This sensor showed high sensitivity compared with the reported electrochemical sensors for the detection of BP. The fabricated sensor was successfully applied for the detection of butyl paraben in real cosmetic samples with good recovery ranging from 96.0 to 100.3%.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 000362918100021 Publication Date 2015-06-23  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0925-4005 ISBN Additional Links UA library record; WoS full record; WoS citing articles  
  Impact Factor 5.401 Times cited 11 Open Access  
  Notes ; ; Approved Most recent IF: 5.401; 2015 IF: 4.097  
  Call Number UA @ admin @ c:irua:127463 Serial 5859  
Permanent link to this record
 

 
Author Bottari, F.; Blust, R.; De Wael, K. pdf  doi
openurl 
  Title Bio(inspired) strategies for the electro-sensing of β-lactam antibiotics Type A1 Journal article
  Year 2018 Publication Current opinion in electrochemistry Abbreviated Journal  
  Volume 10 Issue 10 Pages (down) 143-148  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract The dire previsions of the WHO on the so-called “post-antibiotic era” and the continuous and global rise of anti-microbial resistance, spurs our research community to find better ways to fight these threats. In light of this severe threat to human health many attempts have been made to develop efficient methods to detect antibiotic residues in different streams. The use of electrochemistry seems an inviting approach for on-site and fast monitoring. In this critical review, recent developments in the field of (bio) electro-sensing of 19-lactam antibiotics will be presented, with a focus on aptamers and molecularly imprinted polymers, the two main promises of a new generation of biosensors, yet to be fulfilled.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 000442800000022 Publication Date 2018-05-24  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 2451-9103; 2451-9111 ISBN Additional Links UA library record; WoS full record; WoS citing articles; WoS full record; WoS citing articles  
  Impact Factor Times cited 15 Open Access  
  Notes ; This work was financially supported by the University of Antwerp (BOF) and the Research Foundation – Flanders (FWO). ; Approved Most recent IF: NA  
  Call Number UA @ admin @ c:irua:153744 Serial 5488  
Permanent link to this record
 

 
Author Elia, A.; De Wael, K.; Dowsett, M.; Adriaens, A. doi  openurl
  Title Electrochemical deposition of a copper carboxylate layer on copper as potential corrosion inhibitor Type A1 Journal article
  Year 2011 Publication Journal of solid state electrochemistry Abbreviated Journal J Solid State Electr  
  Volume 16 Issue 1 Pages (down) 143-148  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract Carboxylic acids and sodium carboxylates are used to protect metals against aqueous and atmospheric corrosion. In this paper, we describe the application of a layer of copper carboxylate on the surface of a copper electrode by means of cyclic voltammetry technique and tests which measure the corresponding resistance to aqueous corrosion. Unlike the soaking process, which also forms a film on the surface, the use of cyclic voltammetry allows one to follow the deposition process of the copper carboxylates onto the electrode. The modified electrodes have been characterised with infrared spectroscopy. In addition, the corrosion resistance of the film has been investigated using polarisation resistance and Tafel plot measurements.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 000298651700018 Publication Date 2011-01-25  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1432-8488 ISBN Additional Links UA library record; WoS full record; WoS citing articles  
  Impact Factor 2.316 Times cited 8 Open Access  
  Notes ; Authors would like to acknowledge the Research Foundation-Flanders (FWO) for funding assistance (A. Elia is a FWO aspirant) and V. Vermeersch and S. Van Vlierberghe (Ghent University, Polymer Chemistry and Biomaterials Research Group) for the FTIR-ATR measurements. ; Approved Most recent IF: 2.316; 2011 IF: 2.131  
  Call Number UA @ admin @ c:irua:89618 Serial 5588  
Permanent link to this record
 

 
Author Bottari, F.; Moro, G.; Sleegers, N.; Florea, A.; Cowen, T.; Piletsky, S.; van Nuijs, A.L.N.; De Wael, K. pdf  doi
openurl 
  Title Electropolymerized o-phenylenediamine on graphite promoting the electrochemical detection of nafcillin Type A1 Journal article
  Year 2019 Publication Electroanalysis Abbreviated Journal Electroanal  
  Volume 32 Issue 32 Pages (down) 135-141  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Toxicological Centre  
  Abstract By combining molecular modelling and electrochemistry we envision the creation of modified electrodes tailored for a more sensitive and selective detection of a single analyte. In this study we report on a graphite screen printed electrode modified with electropolymerized o-phenylenediamine, selected by rational design, which promotes the detection of nafcillin (NAF), an antibiotic. Parameters such as monomer concentration, pH and number of electropolymerization cycles were optimized to obtain the highest current signal for the target upon amperometric detection. NAF identification was based on the redox process at +1.1 V (vs pseudo Ag), ascribed to the oxidation of the C-7 side chain. With the optimized modification protocol, a two-fold increase in nafcillin signal could be obtained: the calibration plot in 0.1 M Britton-Robinson buffer pH 4 showed a limit of detection of 80 nM with improved sensitivity and reproducibility (RSD<5 %) compared to the detection at non-modified electrodes.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 000482596300001 Publication Date 2019-08-26  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1040-0397 ISBN Additional Links UA library record; WoS full record; WoS citing articles  
  Impact Factor 2.851 Times cited 1 Open Access  
  Notes ; FB and GM devised the study and performed the experiments, FB wrote the original draft of the paper and analysed the data, NS and AvN performed the MS experiments, AF helped with the optimization of the protocol and correction of the first draft, TC and SP performed the rational monomer design, KdW supervised the work and corrected the final draft. All authors gave their suggestions and corrections to the final version of the paper. This work was financially supported by the University of Antwerp (BOF) and the Research Foundation Flanders (FWO). ; Approved Most recent IF: 2.851  
  Call Number UA @ admin @ c:irua:162870 Serial 5601  
Permanent link to this record
 

 
Author Buczyńska, A.J.; Krata, A.; Van Grieken, R.; Brown, A.; Polezer, G.; De Wael, K.; Potgieter-Vermaak, S. pdf  doi
openurl 
  Title Composition of PM2.5 and PM1 on high and low pollution event days and its relation to indoor air quality in a home for the elderly Type A1 Journal article
  Year 2014 Publication The science of the total environment Abbreviated Journal Sci Total Environ  
  Volume 490 Issue Pages (down) 134-143  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract Many studies probing the link between air quality and health have pointed towards associations between particulate matter (PM) exposure and decreased lung function, aggravation of respiratory diseases like asthma, premature death and increased hospitalisation admissions for the elderly and individuals with cardiopulmonary diseases. Of recent, it is believed that the chemical composition and physical properties of PM may contribute significantly to these adverse health effects. As part of a Belgian Science Policy project (Health effects of particulate matter in relation to physicalchemical characteristics and meteorology), the chemical composition (elemental and ionic compositions) and physical properties (PM mass concentrations) of PM were investigated, indoors and outdoors of old age homes in Antwerp. The case reported here specifically relates to high versus normal/low pollution event periods. PM mass concentrations for PM1 and PM2.5 fractions were determined gravimetrically after collection via impaction. These same samples were hence analysed by EDXRF spectrometry and IC for their elemental and ionic compositions, respectively. During high pollution event days, PM mass concentrations inside the old age home reached 53 μg m− 3 and 32 μg m− 3 whilst outside concentrations were 101 μg m− 3 and 46 μg m− 3 for PM2.5 and PM1, respectively. The sum of nss-sulphate, nitrate and ammonium, dominate the composition of PM, and contribute the most towards an increase in the PM during the episode days constituting 64% of ambient PM2.5 (52 μg m− 3) compared to 39% on non-episode days (10 μg m− 3). Other PM components, such as mineral dust, sea salt or heavy metals were found to be considerably higher during PM episodes but relatively less important. Amongst heavy metals Zn and Pb were found at the highest concentrations in both PM2.5 and PM1. Acidbase ionic balance equations were calculated and point to acidic aerosols during event days and acidic to alkaline aerosols during non-event days. No significant sources of indoor pollutants could be identified inside the old-age home as high correlations were found between outdoor and indoor PM, confirming mainly the outdoor origin of indoor air.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 000347293800015 Publication Date 2014-05-21  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0048-9697 ISBN Additional Links UA library record; WoS full record; WoS citing articles  
  Impact Factor 4.9 Times cited 27 Open Access  
  Notes ; The work reported in this paper was financed by the Belgian Science Policy under the Science for Sustainable Development programme (SD/HE/01), the Flemish Scientific Fund (FWO:G.0873.11). We thank the direction and staff of the elderly homes for their support. The authors are thankful to the partners of the project Lotte Jacobs, Tim Nawrot and Benoit Nemery for taking care of project organization, Andy Delcoo, Jo Dewulf and Hugo De Backer from Royal Meteorological Institute, Brussels, Belgium for supplying the meteorological data. We acknowledge Dr. Laszlo Bencs for assistance regarding backward trajectory analyses and two reviewers for their constructive comments. The authors gratefully acknowledge the NOAA Air Resources Laboratory (ARL) for the provision of the HYSPLIT transport and dispersion model and/or READY website (http://www.ready.noaa.gov) used in this publication. ; Approved Most recent IF: 4.9; 2014 IF: 4.099  
  Call Number UA @ admin @ c:irua:117005 Serial 5544  
Permanent link to this record
 

 
Author Slavkovic, S.; Shoara, A.A.; Churcher, Z.R.; Daems, E.; De Wael, K.; Sobott, F.; Johnson, P.E. url  doi
openurl 
  Title DNA binding by the antimalarial compound artemisinin Type A1 Journal article
  Year 2022 Publication Scientific reports Abbreviated Journal  
  Volume 12 Issue 1 Pages (down) 133  
  Keywords A1 Journal article; Pharmacology. Therapy; Engineering sciences. Technology; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)  
  Abstract Artemisinin (ART) is a vital medicinal compound that is used alone or as part of a combination therapy against malaria. ART is thought to function by attaching to heme covalently and alkylating a range of proteins. Using a combination of biophysical methods, we demonstrate that ART is bound by three-way junction and duplex containing DNA molecules. Binding of ART by DNA is first shown for the cocaine-binding DNA aptamer and extensively studied using this DNA molecule. Isothermal titration calorimetry methods show that the binding of ART is both entropically and enthalpically driven at physiological NaCl concentration. Native mass spectrometry methods confirm DNA binding and show that a non-covalent complex is formed. Nuclear magnetic resonance spectroscopy shows that ART binds at the three-way junction of the cocaine-binding aptamer, and that binding results in the folding of the structure-switching variant of this aptamer. This structure-switching ability was exploited using the photochrome aptamer switch assay to demonstrate that ART can be detected using this biosensing assay. This study is the first to demonstrate the DNA binding ability of ART and should lay the foundation for further work to study implications of DNA binding for the antimalarial activity of ART.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 000740510500120 Publication Date 2022-01-07  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 2045-2322 ISBN Additional Links UA library record; WoS full record; WoS citing articles  
  Impact Factor Times cited Open Access OpenAccess  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:184507 Serial 8851  
Permanent link to this record
 

 
Author Marchetti, A.; Pilehvar, S.; 't Hart, L.; Leyva Pernia, D.; Voet, O.; Anaf, W.; Nuyts, G.; Otten, E.; Demeyer, S.; Schalm, O.; De Wael, K. pdf  url
doi  openurl
  Title Indoor environmental quality index for conservation environments : the importance of including particulate matter Type A1 Journal article
  Year 2017 Publication Building and environment Abbreviated Journal Build Environ  
  Volume 126 Issue Pages (down) 132-146  
  Keywords A1 Journal article; Engineering sciences. Technology; Antwerp Systems and software Modelling (AnSyMo); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Antwerp Cultural Heritage Sciences (ARCHES)  
  Abstract It is commonly known that the conservation state of works of arts exhibited inside museums is strongly influenced by the indoor environmental quality (IEQ). Heritage institutions traditionally record and evaluate their IEQ by monitoring temperature, relative humidity, and -more rarely-light. However, smart use of technology enables monitoring other parameters that give a more complete insight in environmental air aggressiveness. One of this parameters is particulate matter (PM) and especially its concentration, size distribution and chemical composition. In this work, we present a selection of data sets which were obtained in a measuring campaign performed in the War Heritage Institute in Brussels, Belgium. A continuous monitoring of PM concentration with a light scattering based particle counter was performed. In addition the daily mass concentration and size distribution of airborne PM was monitored by means of Harvard impactors. The chemical composition of sampled PM was inferred from the results of XRF and IC analysis. The insights from these datasets are combined with the results of traditional environmental monitoring (temperature, relative humidity and light intensity), and assessed against the recommended guidelines for conservation environments. By using an integrated approach based on the calculation of an IEQ-index, we present a straightforward methodology to evaluate and visualize the IEQ including also continuous PM monitoring. It is clear from the results of this study how including PM in IEQ analysis allows to identify potential risks for museum collections that remain invisible when only traditional parameters are considered.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 000417010000012 Publication Date 2017-09-20  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0360-1323 ISBN Additional Links UA library record; WoS full record; WoS citing articles  
  Impact Factor 4.053 Times cited 10 Open Access  
  Notes ; The study was funded by UAntwerp, Belspo Brain BR/132/A6 and BR/154/A6. ; Approved Most recent IF: 4.053  
  Call Number UA @ admin @ c:irua:146371 Serial 5661  
Permanent link to this record
 

 
Author Rather, J.A.; De Wael, K. pdf  doi
openurl 
  Title Fullerene-C60 sensor for ultra-high sensitive detection of bisphenol-A and its treatment by green technology Type A1 Journal article
  Year 2013 Publication Sensors and actuators : B : chemical Abbreviated Journal Sensor Actuat B-Chem  
  Volume 176 Issue Pages (down) 110-117  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract Endocrine disruptors (EDCs) are environmental pollutants that, once incorporated into an organism, affect the hormonal balance of humans and various species. Its presence in environment is of great importance in water quality related questions. The proposed method describes the development of an accurate, sensitive and selective sensor for the detection of bisphenol-A (BPA) and its treatment by green technology. A fullerene (C60) fabricated electrochemical sensor was developed for the ultrasensitive detection of BPA. The homemade sensor was characterized by scanning electron microscopy, electrochemical impedance spectroscopy and chronocoulometry. The influence of measuring parameters such as pH and C60 loading on the analytical performance of the sensor was evaluated. Various kinetic parameters such as electron transfer number (n); charge transfer coefficient (α); electrode surface area (A) and diffusion coefficient (D) were also calculated. Under the optimal conditions, the oxidation peak current was linear over the concentration range of 74 nM to 0.23 μM with the detection limit (LOD) of 3.7 nM. The fabricated sensor was successfully applied to the determination of BPA in wastewater samples and it has promising analytical applications for the direct determination of BPA at trace level.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 000319867500017 Publication Date 2012-09-07  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0925-4005 ISBN Additional Links UA library record; WoS full record; WoS citing articles  
  Impact Factor 5.401 Times cited 79 Open Access  
  Notes ; The authors are highly thankful for the mobility grant (Non-Europe Postdoc Fellowship) for one of the author (Jahangir Ahmad Rather) supported by the Belgian Federal Science Policy (Belspo) co-funded by the Marie Curie Actions from the European Commission. ; Approved Most recent IF: 5.401; 2013 IF: 3.840  
  Call Number UA @ admin @ c:irua:101055 Serial 5630  
Permanent link to this record
 

 
Author Parrilla, M.; Slosse, A.; Van Echelpoel, R.; Montiel, F.N.; Langley, A.R.; Van Durme, F.; De Wael, K. url  doi
openurl 
  Title Rapid on-site detection of illicit drugs in smuggled samples with a portable electrochemical device Type A1 Journal article
  Year 2022 Publication Chemosensors Abbreviated Journal  
  Volume 10 Issue 3 Pages (down) 108-116  
  Keywords A1 Journal article; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)  
  Abstract The smuggling of illicit drugs urges the development of new tools for rapid on-site identification in cargos. Current methods rely on presumptive color tests and portable spectroscopic techniques. However, these methods sometimes exhibit inaccurate results due to commonly used cutting agents, the colorful nature of the sample or because the drugs are smuggled in common goods. Interestingly, electrochemical sensors can deal with these specific problems. Herein, an electrochemical device is presented that uses affordable screen-printed electrodes for the electrochemical profiling of several illicit drugs by square-wave voltammetry (SWV). The identification of the illicit compound is based on the oxidation potential of the analyte. Hence, a library of electrochemical profiles is built upon the analysis of illicit drugs and common cutting agents. This library allows the design of a tailor-made script that enables the identification of each drug through a user-friendly interface (laptop or mobile phone). Importantly, the electrochemical test is compared by analyzing 48 confiscated samples with other portable devices based on Raman and FTIR spectroscopy as well as a laboratory standard method (i.e., gas chromatography-mass spectrometry). Overall, the electrochemical results, obtained through the analysis of different samples from confiscated cargos at an end-user site, present a promising alternative to current methods, offering low-cost and rapid testing in the field.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 000775813500001 Publication Date 2022-03-11  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 2227-9040 ISBN Additional Links UA library record; WoS full record; WoS citing articles  
  Impact Factor Times cited Open Access OpenAccess  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:187766 Serial 8920  
Permanent link to this record
 

 
Author Castanheiro, A.; Joos, P.; Wuyts, K.; De Wael, K.; Samson, R. pdf  url
doi  openurl
  Title Leaf-deposited semi-volatile organic compounds (SVOCs) : an exploratory study using GCxGC-TOFMS on leaf washing solutions Type A1 Journal article
  Year 2019 Publication Chemosphere Abbreviated Journal Chemosphere  
  Volume 214 Issue 214 Pages (down) 103-110  
  Keywords A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract Airborne particulate matter (PM) includes semi-volatile organic compounds (SVOCs), which can be deposited on vegetation matrices such as plant leaves. In alternative to air-point measurements or artificial passive substrates, leaf monitoring offers a cost-effective, time-integrating means of assessing local air quality. In this study, leaf washing solutions from ivy (Hedera hibernica) leaves exposed during one-month at different land use classes were explored via comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometry (GCxGC-TOFMS). The composition of leaf-deposited SVOCs, corrected for those of unexposed leaves, was compared against routinely monitored pollutants concentrations (PM10, PM2.5, O3, NO2, SO2) measured at co-located air monitoring stations. The first study on leaf-deposited SVOCs retrieved from washing solutions, herein reported, delivered a total of 911 detected compounds. While no significant land use (rural, urban, industrial, traffic, mixed) effects were observed, increasing exposure time (from one to 28 days) resulted in a higher number and diversity of SVOCs, suggesting cumulative time-integration to be more relevant than local source variations between sites. After one day, leaf-deposited SVOCs were mainly due to alcohols, N-containing compounds, carboxylic acids, esters and lactones, while ketones, diketones and hydrocarbons compounds gained relevance after one week, and phenol compounds after one month. As leaf-deposited SVOCs became overall more oxidized throughout exposure time, SVOCs transformation or degradation at the leaf surface is suggested to be an important phenomenon. This study confirmed the applicability of GCxGC-TOFMS to analyze SVOCs from leaf washing solutions, further research should include validation of the methodology and comparison with atmospheric organic pollutants.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 000449891300013 Publication Date 2018-09-13  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0045-6535; 1879-1298 ISBN Additional Links UA library record; WoS full record; WoS citing articles  
  Impact Factor 4.208 Times cited Open Access  
  Notes ; The authors thank the Flemish Environment Agency (VMM) for their collaboration and air quality data; Sam Dekkers and Jonathan Van Waeyenbergh for their help with sample collection. The study was performed using a study set-up funded by the Special Research Fund of the University of Antwerp (KPBOF 2014, no. FFB 140090 'Tree leaf surface properties as dynamic drivers of particulate matter-leaf interaction and phyllosphere microbial communities'). A.C. acknowledges the Research Foundation Flanders (FWO) for her SB PhD fellowship. ; Approved Most recent IF: 4.208  
  Call Number UA @ admin @ c:irua:153509 Serial 5692  
Permanent link to this record
 

 
Author De Wael, K.; De Belder, S.; Pilehar, S.; Van Steenberge, G.; Herrebout, W.; Heering, H.A. url  doi
openurl 
  Title Enzyme-gelatin electrochemical biosensors : scaling down Type A1 Journal article
  Year 2012 Publication Biosensors Abbreviated Journal  
  Volume 2 Issue Pages (down) 101-113  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Molecular Spectroscopy (MolSpec)  
  Abstract In this article we investigate the possibility of scaling down enzyme-gelatin modified electrodes by spin coating the enzyme-gelatin layer. Special attention is given to the electrochemical behavior of the selected enzymes inside the gelatin matrix. A glassy carbon electrode was used as a substrate to immobilize, in the first instance, horse heart cytochrome c (HHC) in a gelatin matrix. Both a drop dried and a spin coated layer was prepared. On scaling down, a transition from diffusion controlled reactions towards adsorption controlled reactions is observed. Compared to a drop dried electrode, a spin coated electrode showed a more stable electrochemical behavior. Next to HHC, we also incorporated catalase in a spin coated gelatin matrix immobilized on a glassy carbon electrode. By spincoating, highly uniform sub micrometer layers of biocompatible matrices can be constructed. A full electrochemical study and characterization of the modified surfaces has been carried out. It was clear that in the case of catalase, gluteraldehyde addition was needed to prevent leaking of the catalase from the gelatin matrix.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos Publication Date 2012-03-15  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 2079-6374 ISBN Additional Links UA library record  
  Impact Factor Times cited Open Access  
  Notes Approved Most recent IF: NA  
  Call Number UA @ admin @ c:irua:96507 Serial 5606  
Permanent link to this record
 

 
Author Kollarahithlu, S.C.; Sathiyamoorthy, S.; Thiruvottriyur Shanmugam, S.; De Wael, K.; Das, J.; Veluswamy, P. isbn  openurl
  Title Foodborne outbreaks : sources and mode of transmission of foodborne pathogenic microorganisms Type H1 Book chapter
  Year 2023 Publication Abbreviated Journal  
  Volume Issue Pages (down) 93-104 T2 - Global food safety : microbial interve  
  Keywords H1 Book chapter; Antwerp Electrochemical and Analytical Sciences Lab (A-Sense Lab)  
  Abstract The foodborne pathogens and microorganisms have played a prevalent role in the ebb and flow of the economy worldwide. The increasing population has strained the food processing industry to produce food in large quantity, which in turn has affected the quality of food. To curb this issue, there is immense pressure to produce and maintain quality food within a short time frame. Hence, high throughput technology is used to determine and timely assess the safety and hygiene of food. Further, the revolution of the food industry has also seen an upsurge of new pathogens and microorganisms, thereby increasing the risk of exposure towards rarest diseases to a larger population. This chapter sheds light on the different types of foodborne pathogens affecting the food industry and its social impact. It further emphasizes the safety measures to be taken on the prevention of the disease from the farm to the processing industries and in turn to the household.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos Publication Date  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN 978-1-003-28314-0 Additional Links UA library record  
  Impact Factor Times cited Open Access  
  Notes Approved no  
  Call Number UA @ admin @ c:irua:200591 Serial 9039  
Permanent link to this record
 

 
Author Buczyńska, A.J.; Geypens, B.; Van Grieken, R.; De Wael, K. pdf  url
doi  openurl
  Title Optimization of sample clean-up for the GC-C-IRMS and GC-IT-MS analysis of PAHs from air particulate matter Type A1 Journal article
  Year 2015 Publication Microchemical journal Abbreviated Journal Microchem J  
  Volume 119 Issue Pages (down) 83-92  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract The optimization of sample clean-up for the analysis of air particulate matter PAHs stable carbon isotope ratio using Solid Phase Extraction (SPE) cartridges is described in this paper. Various adsorbents, such as silica gel, alumina, florisil, commercially available for sample purification were compared. Best performance for the clean-up of 24-h air particulate matter samples was obtained with activated silica-gel columns in terms of selectivity and reproducibility. One step clean-up was optimized for concentration determination and in case of co-elutions, a second step was additionally used for carbon isotope ratio analysis. The method was subsequently validated with standard reference material and was checked for carbon isotope fractionation artefacts. No significant differences in δ13C values were found for unprocessed solutions of PAHs and solution subjected to the extraction and purification procedure. The procedure was tested on air particulate matter samples collected in three different locations in Belgium. Statistically significant differences in carbon isotope ratio of PAHs between Borgerhout location and Zelzate or Gent were noticed, confirming the differences in distribution and diagnostic ratios found during the concentration analyses and different PAH sources in these locations. The results, therefore, seem very promising for the use of δ13C of PAHs as an additional information helpful in source identification of these pollutants  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 000348957800013 Publication Date 2014-11-01  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0026-265x; 0026-265x ISBN Additional Links UA library record; WoS full record; WoS citing articles  
  Impact Factor 3.034 Times cited 7 Open Access  
  Notes ; ; Approved Most recent IF: 3.034; 2015 IF: 2.746  
  Call Number UA @ admin @ c:irua:120641 Serial 5759  
Permanent link to this record
Select All    Deselect All
 |   | 
Details
   print

Save Citations:
Export Records: