toggle visibility
Search within Results:
Display Options:

Select All    Deselect All
 |   | 
Details
   print
  Records Links
Author Anaf, W.; Horemans, B.; Van Grieken, R.; De Wael, K. pdf  doi
openurl 
  Title Chemical boundary conditions for the classification of aerosol particles using computer controlled electron probe microanalysis Type A1 Journal article
  Year 2012 Publication Talanta : the international journal of pure and applied analytical chemistry Abbreviated Journal Talanta  
  Volume 101 Issue Pages 420-427  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract A method for the classification of individual aerosol particles using computer controlled electron probe microanalysis is presented. It is based on chemical boundary conditions (CBC) and enables quick and easy processing of a large set of elemental concentration data (mass%), derived from the X-ray spectra of individual particles. The particles are first classified into five major classes (sea salt related, secondary inorganic, minerals, iron-rich and carbonaceous), after which advanced data mining can be performed by examining the elemental composition of particles within each class into more detail (e.g., by ternary diagrams). The CBC method is validated and evaluated by comparing its results with the output obtained with hierarchical cluster analysis (HCA) for well-known standard particles as well as real aerosol particles collected with a cascade impactor. The CBC method gives reliable results and has a major advantage compared to HCA. CBC is based on boundary conditions that are derived from chemical logical thinking and does not require a translation of a mathematical algorithm output as does HCA. Therefore, the CBC method is more objective and enables comparison between samples without intermediate steps.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 000313084400061 Publication Date 2012-09-30  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0039-9140; 1873-3573 ISBN Additional Links (up) UA library record; WoS full record; WoS citing articles  
  Impact Factor 4.162 Times cited 3 Open Access  
  Notes ; ; Approved Most recent IF: 4.162; 2012 IF: 3.498  
  Call Number UA @ admin @ c:irua:101336 Serial 5511  
Permanent link to this record
 

 
Author Buczyńska, A.J.; Geypens, B.; Van Grieken, R.; De Wael, K. pdf  doi
openurl 
  Title Stable carbon isotopic ratio measurement of polycyclic aromatic hydrocarbons as a tool for source identification and apportionment : a review of analytical methodologies Type A1 Journal article
  Year 2013 Publication Talanta : the international journal of pure and applied analytical chemistry Abbreviated Journal Talanta  
  Volume 105 Issue Pages 435-450  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract The measurement of the ratio of stable isotopes of carbon (13C/12C expressed as a δ13C) in the individual components of a sample may be used as a means to identify the origin of these components. This article reviews the approaches and reports on the successes and failures of source identification and apportionment of Polycyclic Aromatic Hydrocarbons (PAHs) with the use of compound-specific isotope analysis (CSIA). One of the conditions for a precise and accurate analysis of isotope ratios with the use of GC-C-IRMS is the need for well separated peaks, with no co-elutions, and reduced unresolved complex mixture (UCM). Additionally, special care needs to be taken for an investigation of possible isotope fractionation effects introduced during the analytical treatment of samples. With the above-mentioned problems in mind, this review discusses in detail and compares current laboratory methodologies, mainly in the extraction and subsequent clean-up techniques used for environmental samples (air particulate matter, soil and sediments). Sampling strategies, the use of isotopic internal standards and the ranges for precision and accuracy are also reported and discussed.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 000319088500064 Publication Date 2012-10-30  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0039-9140; 1873-3573 ISBN Additional Links (up) UA library record; WoS full record; WoS citing articles  
  Impact Factor 4.162 Times cited 19 Open Access  
  Notes ; ; Approved Most recent IF: 4.162; 2013 IF: 3.511  
  Call Number UA @ admin @ c:irua:102091 Serial 5845  
Permanent link to this record
 

 
Author Mueller, G.; Stahnke, F.; Bleiner, D. pdf  doi
openurl 
  Title Fast steel-cleanness characterization by means of laser-assisted plasma spectrometric methods Type A1 Journal article
  Year 2006 Publication Talanta : the international journal of pure and applied analytical chemistry T2 – 34th Colloquium Spectroscopicum Internationale, SEP 04-09, 2005, Univ Antwerp, Antwerp, BELGIUM Abbreviated Journal Talanta  
  Volume Issue Pages  
  Keywords A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)  
  Abstract Laser-assisted plasma spectrometry is a palette of analytical techniques (L-OES, LA-ICP-MS) capable of fast spatially-resolved elemental analysis in the micrometer range. For fast estimation of the occurrence in steel samples of non-metallic inclusions, which degrade the material's technical properties, simultaneous OES detection and sequential ICP-MS detection were compared. Histograms were obtained for the intensity distribution of the acquired signals (laser pulse statistics). The skewness coefficient of the histograms for Al (indicator of non-metallic inclusions) was found to be clearly dependent on the fraction of non-metallic inclusions in the case of scanning L-OES. For LA-ICP-MS less clear dependence was observed, which was influenced by the acquisition characteristics. In fact, less measurement throughput limited for LA-ICP-MS the counting statistics to an extent that overrides the benefit of higher detection power as compared to L-OES. (c) 2006 Elsevier B.V. All rights reserved.  
  Address  
  Corporate Author Thesis  
  Publisher Pergamon Place of Publication Oxford Editor  
  Language Wos 000242871900015 Publication Date 2006-07-06  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0039-9140; 1873-3573 ISBN Additional Links (up) UA library record; WoS full record; WoS citing articles  
  Impact Factor 4.162 Times cited 12 Open Access  
  Notes Approved Most recent IF: 4.162; 2006 IF: 2.810  
  Call Number UA @ lucian @ c:irua:103122 Serial 4518  
Permanent link to this record
 

 
Author Rahemi, V.; Trashin, S.; Meynen, V.; De Wael, K. pdf  url
doi  openurl
  Title An adhesive conducting electrode material based on commercial mesoporous titanium dioxide as a support for Horseradish peroxidase for bioelectrochemical applications Type A1 Journal article
  Year 2016 Publication Talanta : the international journal of pure and applied analytical chemistry Abbreviated Journal Talanta  
  Volume 146 Issue Pages 689-693  
  Keywords A1 Journal article; Laboratory of adsorption and catalysis (LADCA); AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract An adhesive conducting electrode material containing of graphite, biocompatible ion exchange polymer nafion® and commercial mesoporous TiO2 impregnated with horseradish peroxidase (HRP) is prepared and characterized by amperometric, UVvis and N2 sorption methods. The factors influencing the performance of the resulting biosensor are studied in detail. The optimal electrode material consists of 45% graphite, 50% impregnated HRPTiO2 and 5% nafion®. The optimum conditions for H2O2 reduction are an applied potential of 0.3 V and 0.1 mM hydroquinone. Sensitivity and limit of detection in the optimum conditions are 1 A M−1 cm−2 and 1 µM correspondingly. The N2 sorption results show that the pore volume of TiO2 decreases sharply upon adsorption of HRP. The preparation process of the proposed enzyme electrode is straightforward and potentially can be used for preparation of carbon paste electrodes for bioelectrochemical detections.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 000363815600093 Publication Date 2015-06-24  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0039-9140; 1873-3573 ISBN Additional Links (up) UA library record; WoS full record; WoS citing articles  
  Impact Factor 4.162 Times cited 7 Open Access  
  Notes ; The authors thank the Fund for Scientific Research – Flanders (FWO) (Grant G.0687.13), the GOA-BOF UA 2013-2016 (project-ID 28312) for funding and Ward Huybrechts of the University of Antwerp, Laboratory of Adsorption and Catalysis (LADCA) for help with the N<INF>2</INF> sorption. ; Approved Most recent IF: 4.162  
  Call Number UA @ admin @ c:irua:126495 Serial 5458  
Permanent link to this record
 

 
Author Florea, A.; Cowen, T.; Piletsky, S.; De Wael, K. pdf  url
doi  openurl
  Title Polymer platforms for selective detection of cocaine in street samples adulterated with levamisole Type A1 Journal article
  Year 2018 Publication Talanta : the international journal of pure and applied analytical chemistry Abbreviated Journal Talanta  
  Volume 186 Issue 186 Pages 362-367  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract Accurate drug detection is of utmost importance for fighting against drug abuse. With a high number of cutting agents and adulterants being added to cut or mask drugs in street powders the number of false results is increasing. We demonstrate for the first time the usefulness of employing polymers readily synthesized by electrodeposition to selectively detect cocaine in the presence of the commonly used adulterant levamisole. The polymers were selected by computational modelling to exhibit high binding affinity towards cocaine and deposited directly on the surface of graphene-modified electrodes via electropolymerization. The resulting platforms allowed a distinct electrochemical signal for cocaine, which is otherwise suppressed by levamisole. Square wave voltammetry was used to quantify cocaine alone and in the presence of levamisole. The usefulness of the platforms was demonstrated in the screening of real street samples.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 000435048800049 Publication Date 2018-04-25  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0039-9140; 1873-3573 ISBN Additional Links (up) UA library record; WoS full record; WoS citing articles  
  Impact Factor 4.162 Times cited 9 Open Access  
  Notes ; This project has received funding from the European Union's Horizon 2020 Research and Innovation Programme under the Marie Sklodowska-Curie Grant Agreement no. 753223 Narcoreader. This work was also supported by IOF-SBO (UAntwerp). The authors thank Gert Nuyts for the help with SEM analyses. ; Approved Most recent IF: 4.162  
  Call Number UA @ admin @ c:irua:151250 Serial 5777  
Permanent link to this record
 

 
Author Eliaerts, J.; Meert, N.; Dardenne, P.; Van Durme, F.; Baeten, V.; Samyn, N.; De Wael, K. pdf  url
doi  openurl
  Title Evaluation of a calibration transfer between a bench top and portable Mid-InfraRed spectrometer for cocaine classification and quantification Type A1 Journal article
  Year 2020 Publication Talanta Abbreviated Journal Talanta  
  Volume 209 Issue Pages 120481  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract A portable Fourier Transform Mid-InfraRed (FT-MIR) spectrometer using Attenuated Total Reflectance (ATR) sampling is used for daily routine screening of seized powders. Earlier, ATR-FT-MIR combined with Support Vector Machines (SVM) algorithms resulted in a significant improvement of the screening method to a reliable and straightforward classification and quantification tool for both cocaine and levamisole. However, can this tool be transferred to new (hand-held) devices, without loss of the extensive data set? The objective of this study was to perform a calibration transfer between a newly purchased bench top (BT) spectrometer and a portable (P) spectrometer with existing calibration models. Both instruments are from the same brand and have identical characteristics and acquisition parameters (FT instrument, resolution of 4 cm(-1) and wavenumber range 4000 to 500 cm(-1)). The original SVM classification model (n = 515) and SVM quantification model (n = 378) were considered for the transfer trial. Three calibration transfer strategies were assessed: 1) adjustment of slope and bias; 2) correction of spectra from the new instrument BT to P using Piecewise Direct Standardization (PDS) and 3) building a new mixed instrument model with spectra of both instruments. For each approach, additional cocaine powders were measured (n = 682) and the results were compared with GC-MS and GC-FID. The development of a mixed instrument model was the most successful in terms of performance. The future strategy of a mixed model allows applying the models, developed in the laboratory, to portable instruments that are used on-site, and vice versa. The approach offers opportunities to exchange data within a network of forensic laboratories using other FT-MIR spectrometers.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 000509632900016 Publication Date 2019-10-21  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0039-9140; 1873-3573 ISBN Additional Links (up) UA library record; WoS full record; WoS citing articles  
  Impact Factor 6.1 Times cited 2 Open Access  
  Notes ; ; Approved Most recent IF: 6.1; 2020 IF: 4.162  
  Call Number UA @ admin @ c:irua:166475 Serial 6511  
Permanent link to this record
 

 
Author Sciutto, G.; Legrand, S.; Catelli, E.; Prati, S.; Malegori, C.; Oliveri, P.; Janssens, K.; Mazzeo, R. pdf  url
doi  openurl
  Title Macroscopic mid-FTIR mapping and clustering-based automated data-reduction : an advanced diagnostic tool for in situ investigations of artworks Type A1 Journal article
  Year 2020 Publication Talanta Abbreviated Journal Talanta  
  Volume 209 Issue Pages 120575-120577  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract The present study describes a multivariate strategy that can be used for automatic on-site processing of reflection mode macro FTIR mapping (MA-rFTIR) data obtained during investigation of artworks. The chemometric strategy is based on the integration of principal component analysis (PCA) with a clustering approach in the space subtended by the three lowest-order principal components and allows to automatically identify the regions of interest (ROIs) of the area scanned and to extract the average FTIR spectra related to each ROI. Thanks to the automatic data management, in-field HSI (hyperspectral imaging)-based analyses may be performed even by staff lacking specific advanced chemometric expertise, as it is sometimes the case for conservation scientists or conservators with a scientific background. MA-rFTIR was only recently introduced in the conservation field and, in this work the technique was employed to characterize the surface of metallic artefacts. The analytical protocol was employed as part of a rapid procedure to evaluate the conservation state and the performance of cleaning methods on bronze objects. Both activities are commonly part of restoration campaigns of bronzes and require an on-site analytical procedure for efficient and effective diagnosis. The performance of the method was first evaluated on aged standard samples (bronzes with a layer of green basic copper hydroxysulphate, treated with different organic coatings) and then scrutinized in situ on areas of the 16th century Neptune fountain statue (Piazza del Nettuno, Bologna, Italy) by Gianbologna.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 000509632900088 Publication Date 2019-11-19  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0039-9140; 1873-3573 ISBN Additional Links (up) UA library record; WoS full record; WoS citing articles  
  Impact Factor 6.1 Times cited Open Access  
  Notes ; ; Approved Most recent IF: 6.1; 2020 IF: 4.162  
  Call Number UA @ admin @ c:irua:166476 Serial 6557  
Permanent link to this record
 

 
Author Daems, E.; Dewaele, D.; Barylyuk, K.; De Wael, K.; Sobott, F. pdf  url
doi  openurl
  Title Aptamer-ligand recognition studied by native ion mobility-mass spectrometry Type A1 Journal article
  Year 2021 Publication Talanta Abbreviated Journal Talanta  
  Volume 224 Issue Pages 121917  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract The range of applications for aptamers, small oligonucleotide-based receptors binding to their targets with high specificity and affinity, has been steadily expanding. Our understanding of the mechanisms governing aptamer-ligand recognition and binding is however lagging, stymieing the progress in the rational design of new aptamers and optimization of the known ones. Here we demonstrate the capabilities and limitations of native ion mobility-mass spectrometry for the analysis of their higher-order structure and non-covalent interactions. A set of related cocaine-binding aptamers, displaying a range of folding properties and ligand binding affinities, was used as a case study in both positive and negative electrospray ionization modes. Using carefully controlled experimental conditions, we probed their conformational behavior and interactions with the high-affinity ligand quinine as a surrogate for cocaine. The ratios of bound and unbound aptamers in the mass spectra were used to rank them according to their apparent quinine-binding affinity, qualitatively matching the published ranking order. The arrival time differences between the free aptamer and aptamer-quinine complexes were consistent with a small ligand-induced conformational change, and found to inversely correlate with the affinity of binding. This mass spectrometry-based approach provides a fast and convenient way to study the molecular basis of aptamer-ligand recognition.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 000600787800122 Publication Date 2020-12-02  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0039-9140; 1873-3573 ISBN Additional Links (up) UA library record; WoS full record; WoS citing articles  
  Impact Factor 4.162 Times cited Open Access OpenAccess  
  Notes Approved Most recent IF: 4.162  
  Call Number UA @ admin @ c:irua:174086 Serial 7490  
Permanent link to this record
 

 
Author Felipe Montiel, N.; Parrilla, M.; Beltrán, V.; Nuyts, G.; Van Durme, F.; De Wael, K. pdf  url
doi  openurl
  Title The opportunity of 6-monoacetylmorphine to selectively detect heroin at preanodized screen printed electrodes Type A1 Journal Article
  Year 2021 Publication Talanta Abbreviated Journal Talanta  
  Volume Issue Pages 122005  
  Keywords A1 Journal Article; Antwerp X-ray Analysis, Electrochemistry and Speciation (AXES) ;  
  Abstract The illicit consumption of heroin is an increasing concern in our society. For this reason, rapid analytical methods to seize heroin samples in the field are of paramount importance to hinder drug trafficking, and thus prevent the availability of heroin in the drug market. The present work reports on the enriched electrochemical fingerprint of heroin, allowing its selective detection in street samples, based on the use of electrochemical pretreated screen printed electrodes (p-SPE). The voltammetric identification is built on two oxidation peaks of both heroin and its degradation product 6-monoacetylmorphine (6-MAM), generated in alkaline conditions. Interestingly, an anodic pretreatment of the screen printed electrodes (SPE) shifts the peak potential of paracetamol (the most encountered cutting agent in heroin seizures), allowing the detection of 6-MAM peak, overlapping with the paracetamol signal in the case of untreated SPE. Subsequently, the characterization of the p-SPE with scanning electron microscopy, cyclic voltammetry, electrochemical impedance spectroscopy, Raman and Fourier transform infrared (FTIR) spectroscopy is provided to demonstrate local changes on the surface of the electrode. From an analytical perspective, p-SPE provide higher sensitivity (0.019 μA μM-1), excellent reproducibility (6-MAM, RSD = 2.85%, and heroin RSD = 0.91%, n = 5) and lower limits of detection (LOD) (5.2 μM) in comparison to untreated SPE. The proposed protocol which integrates a tailor-made script is interrogated against common cutting agents, and finally, validated with the screening of 14 street samples, also analyzed by standard methods. Besides, a comparison with portable spectroscopic techniques on the confiscated samples shows the better performance of the electrochemical strategy. Overall, this sensing approach offers promising results for the rapid on-site profiling of suspicious heroin samples, also in the presence of paracetamol.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 000656959000033 Publication Date 2021-01-20  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0039-9140 ISBN Additional Links (up) UA library record; WoS full record; WoS citing articles  
  Impact Factor 4.162 Times cited Open Access OpenAccess  
  Notes This project has received funding from the European Union’s Horizon 2020 research and innovation programme under the grant agreement No 833787, BorderSens. The authors acknowledge financial support from the University of Antwerp (IOF). Approved Most recent IF: 4.162  
  Call Number AXES @ axes @c:irua:174844 Serial 6663  
Permanent link to this record
 

 
Author Van Echelpoel, R.; de Jong, M.; Daems, D.; van Espen, P.; De Wael, K. pdf  url
doi  openurl
  Title Unlocking the full potential of voltammetric data analysis : a novel peak recognition approach for (bio)analytical applications Type A1 Journal article
  Year 2021 Publication Talanta Abbreviated Journal Talanta  
  Volume 233 Issue Pages 122605  
  Keywords A1 Journal article; Engineering sciences. Technology; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract Bridging the gap between complex signal data output and clear interpretation by non-expert end-users is a major challenge many scientists face when converting their scientific technology into a real-life application. Currently, pattern recognition algorithms are the most frequently encountered signal data interpretation algorithms to close this gap, not in the least because of their straight-forward implementation via convenient software packages. Paradoxically, just because their implementation is so straight-forward, it becomes cumbersome to integrate the expert's domain-specific knowledge. In this work, a novel signal data interpretation approach is presented that uses this domain-specific knowledge as its fundament, thereby fully exploiting the unique expertise of the scientist. The new approach applies data preprocessing in an innovative way that transcends its usual purpose and is easy to translate into a software application. Multiple case studies illustrate the straight-forward application of the novel approach. Ultimately, the approach is highly suited for integration in various (bio)analytical applications that require interpretation of signal data.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 000668000500108 Publication Date 2021-06-11  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0039-9140; 1873-3573 ISBN Additional Links (up) UA library record; WoS full record; WoS citing articles  
  Impact Factor 4.162 Times cited Open Access OpenAccess  
  Notes Approved Most recent IF: 4.162  
  Call Number UA @ admin @ c:irua:179417 Serial 8712  
Permanent link to this record
 

 
Author Janssens, K.; Bogaerts, A.; van Grieken, R. doi  openurl
  Title Colloquium Spectroscopicum Internationale 34, Antwerp, Belgium, 4-9 September 2005: preface Type Editorial
  Year 2006 Publication Talanta : the international journal of pure and applied analytical chemistry Abbreviated Journal Talanta  
  Volume 70 Issue 5 Pages 907-908  
  Keywords Editorial; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation); Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)  
  Abstract  
  Address  
  Corporate Author Thesis  
  Publisher Pergamon Place of Publication Oxford Editor  
  Language Wos 000242871900001 Publication Date 2006-11-01  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0039-9140; ISBN Additional Links (up) UA library record; WoS full record  
  Impact Factor 4.162 Times cited Open Access  
  Notes Approved Most recent IF: 4.162; 2006 IF: 2.810  
  Call Number UA @ lucian @ c:irua:61094 Serial 392  
Permanent link to this record
 

 
Author Kontozova-Deutsch, V.; Deutsch, F.; Bencs, L.; Krata, A.; Van Grieken, R.; De Wael, K. pdf  doi
openurl 
  Title Optimization of the ion chromatographic quantification of airborne fluoride, acetate and formate in the Metropolitan Museum of Art, New York Type A1 Journal article
  Year 2011 Publication Talanta : the international journal of pure and applied analytical chemistry Abbreviated Journal Talanta  
  Volume 86 Issue Pages 372-376  
  Keywords A1 Journal article; AXES (Antwerp X-ray Analysis, Electrochemistry and Speciation)  
  Abstract Ion chromatographic (IC) methods have been compared in order to achieve an optimal separation of fluoride, acetate and formate under various elution conditions on two formerly introduced analytical columns (i and ii) and a novel one (iii): (i) an IonPac AS14 (250 mm × 4 mm I.D.), (ii) Allsep A-2 (150 mm × 4.6 mm I.D.), and (iii) an IC SI-50 4E (250 mm (length) × 4 mm (internal diameter – I.D.)). The IC conditions for the separation of the anions concerned were optimized on the IC SI-50 4E column. A near baseline separation of these anions was attained on the IonPac AS14, whereas the peaks of fluoride and acetate could not be resolved on the Allsep A-2. A baseline separation for the three anions was achieved on the IC SI-50 4E column, when applying an eluent mixture of 3.2 mmol/L Na2CO3 and 1.0 mmol/L NaHCO3 with a flow rate of 1.0 mL/min. The highest precision of 1.7, 3.0 and 2.8% and the best limits of detection (LODs) of 0.014, 0.22 and 0.17 mg/L for fluoride, acetate and formate, respectively, were obtained with the IC SI-50 4E column. Hence, this column was applied for the determination of the acetic and formic acid contents of air samples taken by means of passive gaseous sampling at the Metropolitan Museum of Art in New York, USA. Atmospheric concentrations of acetic and formic acid up to 1050 and 450 μg/m3, respectively, were found in non-aerated showcases of the museum. In galleries and outdoors, rather low levels of acetic and formic acid were detected with average concentrations of 50 and 10 μg/m3, respectively. The LOD data of acetate and formate on the IC SI-50 4E column correspond to around 0.5 μg/m3 for both acetic and formic acid in air samples.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Wos 000298126300048 Publication Date 2011-09-24  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0039-9140; 1873-3573 ISBN Additional Links (up) UA library record; WoS full record; WoS citing articles  
  Impact Factor 4.162 Times cited 19 Open Access  
  Notes ; The authors gratefully acknowledge the support of Marco Leona and the staff of the Metropolitan Museum of Art in New York during the sampling campaigns. The technical assistance and advice by Dr. Takashi Kotsuka and Shodex Benelux are acknowledged as well. ; Approved Most recent IF: 4.162; 2011 IF: 3.794  
  Call Number UA @ admin @ c:irua:92066 Serial 5762  
Permanent link to this record
 

 
Author Bleiner, D.; Macri, M.; Gasser, P.; Sautter, V.; Maras, A. pdf  doi
openurl 
  Title FIB, TEM and LA-ICPMS investigations on melt inclusions in Martian meteorites – Analytical capabilities and geochemical insights Type A1 Journal article
  Year 2006 Publication Talanta : the international journal of pure and applied analytical chemistry Abbreviated Journal Talanta  
  Volume Issue Pages  
  Keywords A1 Journal article; Plasma Lab for Applications in Sustainability and Medicine – Antwerp (PLASMANT)  
  Abstract In order to obtain full information coverage on melt inclusions in Martian meteorites (subgroup nakhlites) complementary micro-analytical techniques were used, i.e. focused ion beam, transmission electron microscopy and laser ablation. Using focused ion beam several lamellae for transmission electron microscopy were prepared and secondary electron images of cross-sections could be acquired. Laser ablation-inductively coupled plasma mass spectrometry analyses were performed on selected inclusions to obtain mass-oriented bulk composition of inclusions at depth. The differences in composition between melt inclusions in olivine and augite crystals would suggest a xenocrystic origin for olivine. Furthermore, electron diffraction patterns clearly indicated that the SiO2-rich phase in inclusions from augite in meteorites from Northwest Africa site is re-crystallized, whereas it is still vitreous in the inclusions from Nakhla sampling site. Therefore, different post-entrapment evolutions were active for the two nakhlite meteorite sets, the Nakhla and the NWA817 set. Melt inclusions in Nakhla olivine presented alteration veins, which were presumably produced before their landing on Earth. If this is the case, this would indicate a alteration stage already on Mars with all the consequence in terms of climate history. Melt inclusions in Nakhla augite resulted unaffected by any alteration or modification following the entrapment, and therefore represent the best candidate to indicate the pristine magma composition. (c) 2005 Elsevier B.V. All rights reserved.  
  Address  
  Corporate Author Thesis  
  Publisher Pergamon Place of Publication Oxford Editor  
  Language Wos 000235509900028 Publication Date 2005-09-24  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0039-9140; 1873-3573 ISBN Additional Links (up) UA library record; WoS full record; WoS citing articles  
  Impact Factor 4.162 Times cited 9 Open Access  
  Notes Approved Most recent IF: 4.162; 2006 IF: 2.810  
  Call Number UA @ lucian @ c:irua:95092 Serial 4519  
Permanent link to this record
Select All    Deselect All
 |   | 
Details
   print

Save Citations:
Export Records: